  "dataset_name": "Uptime Commercial Door Wind Load Evidence Ledger",
  "version": "1.1.0",
  "compiled_by": "Uptime Dock & Door Research",
  "compiled_date": "2026-09-19",
  "last_verified": "2026-09-19",
  "spatial_coverage": "United States national framework, with Florida and Texas program examples",
  "temporal_coverage": "Source editions and effective dates are attached at row level; web sources last verified 2026-09-19",
  "description": "A source-linked evidence ledger for commercial sectional, garage, rolling, and related exterior vehicle-access door wind-load requirements, terminology, documents, jurisdictional examples, and verification tasks.",
  "formulas": {
    "magnitude_change_psf": "abs(ASCE 7-22 source value) - abs(ASCE 7-16 source value)",
    "pct_change_in_magnitude": "(abs(ASCE 7-22 source value) - abs(ASCE 7-16 source value)) / abs(ASCE 7-16 source value) * 100",
    "positive_margin_for_a_separate_project_check": "door_labeled_positive_dp - project_required_positive_dp",
    "negative_margin_for_a_separate_project_check": "abs(door_labeled_negative_dp) - abs(project_required_negative_dp)"
  },
  "missing_value_rule": "Unknown, unavailable, not applicable, and unverified are distinct states. Never convert missing evidence to zero. A missing label or report is an evidence gap, not proof of zero capacity.",
  "methodology": "Uptime joined matched scenarios from DASMA TDS 155v and 155y, published only the derived changes with source-page locators, and assembled the other tables from current official model-code, standard-publisher, state/county program, and DASMA sources. Manufacturer- or program-specific statements remain scoped to the named document.",
  "limits": "This dataset does not calculate project wind pressure, design anchors or supporting structure, certify a product, inspect an installation, or replace the adopted code, ASCE 7, manufacturer instructions, a registered design professional, or the authority having jurisdiction.",
  "license": null,
  "license_note": "No public reuse license is asserted. Third-party source material remains subject to its original rights.",
  "row_counts": {
    "asce_7_16_vs_7_22_pressure_delta": 428,
    "jurisdiction_and_authority_crosswalk": 39,
    "document_register": 42,
    "verification_checklist": 20,
    "terminology_crosswalk": 13,
    "source_register": 26
  },
  "total_evidence_rows": 568,
  "data_dictionary_file": "uptime-commercial-door-wind-load-data-dictionary.csv",
  "tables": {
    "asce_7_16_vs_7_22_pressure_delta": [
      {
        "record_id": "D001",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D002",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D003",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D004",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D005",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D006",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.934579,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D007",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D008",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.854701,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D009",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D010",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.787402,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D011",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.757576,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D012",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.671141,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D013",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.653595,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D014",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.578035,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D015",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D016",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D017",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.5,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D018",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.442478,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D019",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D020",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.392157,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D021",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.395257,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D022",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D023",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D024",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.314465,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D025",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.320513,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D026",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.284091,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D027",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D028",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D029",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D030",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D031",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D032",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.990099,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D033",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.010101,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D034",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D035",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D036",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.833333,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D037",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D038",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.70922,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D039",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D040",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D041",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.595238,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D042",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D043",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.52356,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D044",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.469484,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D045",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.462963,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D046",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D047",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.413223,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D048",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.37037,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D049",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D050",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.333333,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D051",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.334448,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D052",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.3003,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 3,
        "source_page_asce_7_22": 3,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D053",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D054",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.980392,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D055",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.010101,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D056",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.892857,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D057",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.917431,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D058",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.813008,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D059",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.840336,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D060",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.481481,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D061",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.538462,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D062",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.360544,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D063",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.315789,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D064",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.162791,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D065",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.129944,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D066",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.5,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D067",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.477833,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D068",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.310044,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D069",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.298701,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D070",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.149425,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D071",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.532567,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D072",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.355932,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D073",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.369863,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D074",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.212121,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D075",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.533742,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D076",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.358696,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D077",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.385042,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D078",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.22549,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D079",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D080",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D081",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D082",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.943396,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D083",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.904762,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D084",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.709402,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D085",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.877193,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D086",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.787402,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D087",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.806452,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D088",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.438849,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D089",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.369863,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D090",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.226994,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D091",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.183432,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D092",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.587302,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D093",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.030928,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D094",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.382488,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D095",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.357466,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D096",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.619433,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D097",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.6,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D098",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.079137,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D099",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.428571,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D100",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.282051,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D101",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.282051,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D102",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.436782,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D103",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.15942,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D104",
        "door_type": "Garage door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.298701,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 4,
        "source_page_asce_7_22": 4,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D105",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D106",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D107",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D108",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D109",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D110",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D111",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D112",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D113",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D114",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D115",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.826446,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D116",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.729927,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D117",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D118",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D119",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.621118,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D120",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.549451,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D121",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.546448,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D122",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.483092,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D123",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D124",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.42735,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D125",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D126",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.381679,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D127",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.387597,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D128",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.342466,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D129",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.34965,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D130",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.309598,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D131",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D132",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D133",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D134",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D135",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D136",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D137",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D138",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.970874,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D139",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.0,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D140",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.892857,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D141",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.854701,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D142",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D143",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D144",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.657895,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D145",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.641026,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D146",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D147",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.564972,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D148",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D149",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.5,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D150",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.446429,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D151",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.446429,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D152",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.398406,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D153",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D154",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.357143,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D155",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D156",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.322581,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D157",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D158",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D159",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D160",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D161",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D162",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D163",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D164",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.030928,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D165",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D166",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D167",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D168",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D169",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.775194,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D170",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D171",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.675676,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D172",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D173",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.595238,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D174",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.534759,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D175",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.526316,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D176",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D177",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.469484,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D178",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.421941,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D179",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.421941,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D180",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.378788,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D181",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.380228,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D182",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.342466,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 7,
        "source_page_asce_7_22": 7,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D183",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D184",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D185",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D186",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.970874,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D187",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.0,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D188",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.884956,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D189",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.917431,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D190",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.612903,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D191",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.680672,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D192",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.481481,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D193",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.428571,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D194",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.265823,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D195",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.234568,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D196",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.092896,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D197",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.075269,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D198",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -0.952381,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D199",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.415094,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D200",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.25523,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D201",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.25523,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D202",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.111111,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D203",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.492537,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D204",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.320132,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D205",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.006711,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D206",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.47929,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D207",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.510574,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D208",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.336898,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D209",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D210",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D211",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D212",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.010101,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D213",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.030928,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D214",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.834862,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D215",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.886792,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D216",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.680672,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D217",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.869565,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D218",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.775194,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D219",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.481481,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D220",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.315789,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D221",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.273885,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D222",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.136364,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D223",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.111111,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D224",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.485149,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D225",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.463415,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D226",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.304348,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D227",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.298701,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D228",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.158301,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D229",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.158301,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D230",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.37457,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D231",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.384083,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D232",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.234568,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D233",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.25,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D234",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.5,
        "pct_change_in_magnitude": -1.392758,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D235",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D236",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D237",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D238",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D239",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": true,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D240",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.980392,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D241",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -1.0,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D242",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.785714,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D243",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.917431,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D244",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.639344,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D245",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.78125,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D246",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 130,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.398601,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D247",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.342282,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D248",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 140,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.204819,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D249",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.169591,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D250",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 150,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.052632,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D251",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -1.030928,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D252",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 160,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -0.925926,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D253",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.2,
        "pct_change_in_magnitude": -0.913242,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D254",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 170,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.229508,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D255",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.219512,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D256",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 180,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.459854,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D257",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.3,
        "pct_change_in_magnitude": -1.094891,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D258",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 190,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.311475,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D259",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.315789,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D260",
        "door_type": "Commercial door",
        "exposure_category": "B",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 200,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.4,
        "pct_change_in_magnitude": -1.183432,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 8,
        "source_page_asce_7_22": 8,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D261",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D262",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D263",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D264",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.699301,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D265",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.719424,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D266",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.636943,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D267",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.909091,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D268",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D269",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D270",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D271",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.75188,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D272",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D273",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D274",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D275",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D276",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D277",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D278",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D279",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D280",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D281",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D282",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D283",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.671141,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D284",
        "door_type": "Garage door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 5,
        "source_page_asce_7_22": 5,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D285",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D286",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D287",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D288",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D289",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D290",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D291",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D292",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D293",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.675676,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D294",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D295",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D296",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.552486,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D297",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.653595,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D298",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.578035,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D299",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.595238,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D300",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.526316,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D301",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.540541,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D302",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "9 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.478469,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D303",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.684932,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D304",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.613497,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D305",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D306",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.555556,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D307",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.564972,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D308",
        "door_type": "Garage door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "16 ft x 7 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.507614,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 6,
        "source_page_asce_7_22": 6,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D309",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.952381,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D310",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.840336,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D311",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.862069,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D312",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D313",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D314",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.694444,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D315",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D316",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D317",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D318",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D319",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D320",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D321",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D322",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.793651,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D323",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D324",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D325",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D326",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.662252,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D327",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D328",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D329",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D330",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D331",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D332",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D333",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.854701,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D334",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D335",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.78125,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D336",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D337",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D338",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.645161,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D339",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D340",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D341",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.769231,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D342",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.680272,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D343",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D344",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D345",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D346",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D347",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D348",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D349",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D350",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.78125,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D351",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D352",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D353",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.724638,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D354",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D355",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D356",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D357",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D358",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D359",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D360",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D361",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D362",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": -0.1,
        "pct_change_in_magnitude": -0.75188,
        "change_direction": "down",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D363",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D364",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D365",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D366",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D367",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D368",
        "door_type": "Commercial door",
        "exposure_category": "C",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 9,
        "source_page_asce_7_22": 9,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D369",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.78125,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D370",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.689655,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D371",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.70922,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D372",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.625,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D373",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.645161,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D374",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.571429,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D375",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.591716,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D376",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.520833,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D377",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.543478,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D378",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.478469,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D379",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D380",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.719424,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D381",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D382",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.653595,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D383",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.666667,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D384",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.595238,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D385",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.609756,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D386",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.543478,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D387",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.561798,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D388",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.5,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D389",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D390",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.763359,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D391",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D392",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.694444,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D393",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.704225,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D394",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.632911,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D395",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D396",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.578035,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D397",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.591716,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D398",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 15,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.529101,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D399",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.714286,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D400",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.632911,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D401",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.649351,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D402",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D403",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.591716,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D404",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.520833,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D405",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.540541,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D406",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.478469,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D407",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.497512,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D408",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "8 ft x 8 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.438596,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D409",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.740741,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D410",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.657895,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D411",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.671141,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D412",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.598802,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D413",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.609756,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D414",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.543478,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D415",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.558659,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D416",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.497512,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D417",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.512821,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D418",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "10 ft x 10 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.456621,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D419",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D420",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 100,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.699301,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D421",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D422",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 105,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.632911,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D423",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.0,
        "pct_change_in_magnitude": 0.0,
        "change_direction": "unchanged",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D424",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 110,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.578035,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D425",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.588235,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D426",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 115,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.529101,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D427",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "positive",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.540541,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      },
      {
        "record_id": "D428",
        "door_type": "Commercial door",
        "exposure_category": "D",
        "mean_roof_height_ft": 25,
        "door_size": "14 ft x 14 ft",
        "basic_wind_speed_mph": 120,
        "pressure_direction": "negative",
        "magnitude_change_psf_7_22_minus_7_16": 0.1,
        "pct_change_in_magnitude": 0.485437,
        "change_direction": "up",
        "both_at_9_6_chart_floor": false,
        "source_asce_7_16": "DASMA TDS 155v",
        "source_asce_7_22": "DASMA TDS 155y",
        "source_page_asce_7_16": 10,
        "source_page_asce_7_22": 10,
        "verified_date": "2026-09-19",
        "scope_note": "Derived comparison only. See both source pages for the published pressure values and chart assumptions."
      }
    ],
    "jurisdiction_and_authority_crosswalk": [
      {
        "record_id": "J01",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Adoption status",
        "what_the_source_says": "The IBC is a model code adopted by governmental jurisdictions and may be amended locally.",
        "authority_type": "Model code, not automatically enforceable everywhere",
        "issuing_body": "International Code Council",
        "source_document": "International Building Code overview",
        "source_locator": "Adoptions of the IBC",
        "source_url": "https://www.iccsafe.org/products-and-services/i-codes/ibc/",
        "edition_or_effective_date": "Current overview",
        "verified_date": "2026-09-19",
        "scope_limit": "Record the edition and amendments adopted for the project."
      },
      {
        "record_id": "J02",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Current model-code test provision",
        "what_the_source_says": "The 2024 IBC uses Chapter 16 design pressure and requires the exterior assembly test described in §1709.5.2.",
        "authority_type": "Model-code provision",
        "issuing_body": "International Code Council",
        "source_document": "2024 International Building Code, Chapter 17",
        "source_locator": "§1709.5.2",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_effective_date": "2024 IBC",
        "verified_date": "2026-09-19",
        "scope_limit": "The project may use a different adopted edition."
      },
      {
        "record_id": "J03",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Garage and rolling door test methods",
        "what_the_source_says": "The 2024 IBC names ASTM E330 or ANSI/DASMA 108 and applies ANSI/DASMA 108 pass/fail criteria.",
        "authority_type": "Model-code provision",
        "issuing_body": "International Code Council",
        "source_document": "2024 International Building Code, Chapter 17",
        "source_locator": "§1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_effective_date": "2024 IBC",
        "verified_date": "2026-09-19",
        "scope_limit": "The exact adopted code and report must match the project."
      },
      {
        "record_id": "J04",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Test pressure and duration",
        "what_the_source_says": "The 2024 IBC says each assembly is tested for 10 seconds at a load equal to 1.5 times design pressure.",
        "authority_type": "Model-code provision",
        "issuing_body": "International Code Council",
        "source_document": "2024 International Building Code, Chapter 17",
        "source_locator": "§1709.5.2",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_effective_date": "2024 IBC",
        "verified_date": "2026-09-19",
        "scope_limit": "This is not a second product design rating."
      },
      {
        "record_id": "J05",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Permanent label fields",
        "what_the_source_says": "The 2024 IBC label identifies manufacturer, model/series, positive and negative design pressure, installation-drawing reference, and test standard.",
        "authority_type": "Model-code provision",
        "issuing_body": "International Code Council",
        "source_document": "2024 International Building Code, Chapter 17",
        "source_locator": "§1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_effective_date": "2024 IBC",
        "verified_date": "2026-09-19",
        "scope_limit": "A label does not prove the project pressure, configuration, support, or installation matches."
      },
      {
        "record_id": "J06",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Impact scope in Chapter 17",
        "what_the_source_says": "The 2024 IBC §1709.5.3 addresses protection of exterior glazed openings in wind-borne-debris regions.",
        "authority_type": "Model-code provision",
        "issuing_body": "International Code Council",
        "source_document": "2024 International Building Code, Chapter 17",
        "source_locator": "§1709.5.3",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_effective_date": "2024 IBC",
        "verified_date": "2026-09-19",
        "scope_limit": "Do not expand this model-code text into a universal impact requirement for every opaque commercial door."
      },
      {
        "record_id": "J07",
        "compliance_path": "U.S. model-code framework",
        "requirement_topic": "Site hazard lookup",
        "what_the_source_says": "The ASCE Hazard Tool supplies site-specific data and lets the user select ASCE 7-10, 7-16, or 7-22.",
        "authority_type": "Official standard-publisher tool",
        "issuing_body": "American Society of Civil Engineers",
        "source_document": "About the ASCE Hazard Tool",
        "source_locator": "Using the Tool; Data Sources",
        "source_url": "https://www.asce.org/publications-and-news/asce-hazard-tool/about",
        "edition_or_effective_date": "Supports ASCE 7-10, 7-16, and 7-22",
        "verified_date": "2026-09-19",
        "scope_limit": "The tool supplies parameters, not a door approval."
      },
      {
        "record_id": "J08",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "ASCE 7-16 guide path",
        "what_the_source_says": "TDS 155v charts selected garage and commercial door scenarios under ASCE 7-16.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155v — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-16",
        "source_locator": "Cover and pp. 3–10",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS155v.pdf",
        "edition_or_effective_date": "Rev. 4/26; chart editions identified in PDF",
        "verified_date": "2026-09-19",
        "scope_limit": "Use only inside the guide’s assumptions and the project’s adopted-code path."
      },
      {
        "record_id": "J09",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "ASCE 7-22 guide path",
        "what_the_source_says": "TDS 155y charts selected garage and commercial door scenarios under ASCE 7-22 and the 2024 IBC.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "source_locator": "Cover and pp. 3–10",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_effective_date": "Rev. 1/26",
        "verified_date": "2026-09-19",
        "scope_limit": "Use only inside the guide’s assumptions and the project’s adopted-code path."
      },
      {
        "record_id": "J10",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Charted 9.6-psf value",
        "what_the_source_says": "TDS 155y calls 9.6 psf the minimum value charted within the guide.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "source_locator": "General note 7",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_effective_date": "Rev. 1/26",
        "verified_date": "2026-09-19",
        "scope_limit": "It is not a universal requirement for every project or proof that every commercial door must carry a rating."
      },
      {
        "record_id": "J11",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Exposure C multipliers",
        "what_the_source_says": "TDS 155y applies 1.49 at 15-ft mean roof height and 1.44 at 25 ft relative to its Exposure B chart values.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "source_locator": "Exposure C chart notes",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_effective_date": "Rev. 1/26",
        "verified_date": "2026-09-19",
        "scope_limit": "Applies to the guide scenarios and assumptions, not every possible building."
      },
      {
        "record_id": "J12",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Exposure D multipliers",
        "what_the_source_says": "TDS 155y applies 1.81 at 15-ft mean roof height and 1.73 at 25 ft relative to its Exposure B chart values.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "source_locator": "Exposure D chart notes",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_effective_date": "Rev. 1/26",
        "verified_date": "2026-09-19",
        "scope_limit": "Applies to the guide scenarios and assumptions, not every possible building."
      },
      {
        "record_id": "J13",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Exposure responsibility",
        "what_the_source_says": "DASMA assigns exposure-category determination to the project design professional or building official.",
        "authority_type": "Industry technical guidance",
        "issuing_body": "DASMA",
        "source_document": "TDS 193 — Wind Exposure Categories",
        "source_locator": "Conclusion",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/03/TDS193.pdf",
        "edition_or_effective_date": "Rev. 1/22",
        "verified_date": "2026-09-19",
        "scope_limit": "A supplier can select a product after inputs are supplied; it should not invent the project exposure."
      },
      {
        "record_id": "J14",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Effective wind area",
        "what_the_source_says": "For a typical single-unit garage-door assembly, TDS 178 treats the effective wind area as the overall door area.",
        "authority_type": "Industry technical guidance",
        "issuing_body": "DASMA",
        "source_document": "TDS 178 — Garage Door Wind Load Determination: Effective Wind Area",
        "source_locator": "Conclusion",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/10/TDS178.pdf",
        "edition_or_effective_date": "Rev. 10/22",
        "verified_date": "2026-09-19",
        "scope_limit": "Complex or mulled assemblies may require different treatment."
      },
      {
        "record_id": "J15",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Label-alone limitation",
        "what_the_source_says": "TDS 181 warns not to rely on a label alone and supplies 15 physical configuration checks.",
        "authority_type": "Industry inspection guidance",
        "issuing_body": "DASMA",
        "source_document": "TDS 181 — General Code Inspection Guidelines for Wind Load",
        "source_locator": "Opening note and checklist",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "edition_or_effective_date": "Rev. 6/25",
        "verified_date": "2026-09-19",
        "scope_limit": "Inspection guidance does not replace the AHJ or an engineering evaluation."
      },
      {
        "record_id": "J16",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Supporting construction",
        "what_the_source_says": "The door’s supporting framing and load path are separate project responsibilities from the rated door assembly.",
        "authority_type": "Industry technical guidance",
        "issuing_body": "DASMA",
        "source_document": "TDS 168 — Wind Loads on Garage Doors: FAQ",
        "source_locator": "Q16",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "edition_or_effective_date": "Rev. 3/26",
        "verified_date": "2026-09-19",
        "scope_limit": "Exact project drawings and manufacturer reactions control."
      },
      {
        "record_id": "J17",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "PSF rather than mph",
        "what_the_source_says": "A bare mph claim does not establish the pressure rating required for a project opening.",
        "authority_type": "Industry technical guidance",
        "issuing_body": "DASMA",
        "source_document": "TDS 194 — PSF versus MPH in Door Specifications",
        "source_locator": "Entire sheet",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/08/TDS194.pdf",
        "edition_or_effective_date": "Current PDF accessed 2026-09-19",
        "verified_date": "2026-09-19",
        "scope_limit": "Preserve the project ±PSF and pressure basis."
      },
      {
        "record_id": "J18",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Operational versus static wind",
        "what_the_source_says": "Closed-door static pressure performance and operation under wind are separate questions.",
        "authority_type": "Trade-association technical article",
        "issuing_body": "DASMA / Door + Access Systems Magazine",
        "source_document": "Tech Corner — Understanding operational wind load",
        "source_locator": "Operational wind-load discussion",
        "source_url": "https://mydigimag.rrd.com/article/Tech+Corner/4995460/847956/article.html",
        "edition_or_effective_date": "Summer 2025",
        "verified_date": "2026-09-19",
        "scope_limit": "No separately titled operational-wind test standard was identified on the current DASMA standards index as of the verification date. This index check does not establish the contents of every broader product standard."
      },
      {
        "record_id": "J19",
        "compliance_path": "DASMA guide framework",
        "requirement_topic": "Tornado check",
        "what_the_source_says": "TDS 155y directs Risk Category III and IV users to check ASCE 7-22 Chapter 32 where tornado pressure may govern.",
        "authority_type": "Industry technical guide",
        "issuing_body": "DASMA",
        "source_document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "source_locator": "General note 4",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_effective_date": "Rev. 1/26",
        "verified_date": "2026-09-19",
        "scope_limit": "This is a guide note tied to ASCE 7-22 and the project risk category."
      },
      {
        "record_id": "J20",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Current edition",
        "what_the_source_says": "The Florida Building Commission identifies the 8th Edition (2023) Florida Building Code as effective December 31, 2023.",
        "authority_type": "State code authority",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Building Commission home page",
        "source_locator": "Effective-date notice",
        "source_url": "https://www.floridabuilding.org/",
        "edition_or_effective_date": "8th Edition (2023), effective 2023-12-31",
        "verified_date": "2026-09-19",
        "scope_limit": "Supplements and the 2026 update process can change future requirements."
      },
      {
        "record_id": "J21",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Product approval record",
        "what_the_source_says": "The state Product Approval search provides current product/application records.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Search interface",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "A search result must be opened and matched to the exact product and revision."
      },
      {
        "record_id": "J22",
        "compliance_path": "Florida statewide",
        "requirement_topic": "HVHZ field",
        "what_the_source_says": "The state database includes whether a product is approved for use in the HVHZ.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Approved for use in HVHZ field",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "HVHZ approval is not inferred from outside-HVHZ approval."
      },
      {
        "record_id": "J23",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Outside-HVHZ field",
        "what_the_source_says": "The state database separately identifies approval outside the HVHZ.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Approved for use outside HVHZ field",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "The project location and record limits still control."
      },
      {
        "record_id": "J24",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Impact field",
        "what_the_source_says": "The state database includes an impact-resistant field.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Impact Resistant field",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "N/A, No, and Yes are different states and must not be collapsed."
      },
      {
        "record_id": "J25",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Positive and negative design pressure",
        "what_the_source_says": "The state database includes separate positive and negative design-pressure fields.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Design Pressure + / - fields",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "The values are product-record values, not a project pressure schedule."
      },
      {
        "record_id": "J26",
        "compliance_path": "Florida statewide",
        "requirement_topic": "Limits of use and instructions",
        "what_the_source_says": "The exact product record links evaluation reports and installation instructions.",
        "authority_type": "State product-approval program",
        "issuing_body": "Florida Building Commission",
        "source_document": "Florida Product Approval Search",
        "source_locator": "Product detail records",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_effective_date": "2023 Florida Building Code",
        "verified_date": "2026-09-19",
        "scope_limit": "The exact report, model, size, options, limits, and instructions must match."
      },
      {
        "record_id": "J27",
        "compliance_path": "Miami-Dade Product Control",
        "requirement_topic": "NOA workflow",
        "what_the_source_says": "Miami-Dade runs a product-specific Product Control/NOA search.",
        "authority_type": "County product-approval program",
        "issuing_body": "Miami-Dade County Product Control",
        "source_document": "Product Approval and Product Control Search",
        "source_locator": "Product approval program page",
        "source_url": "https://www.miamidade.gov/global/economy/building/product-approval.page",
        "edition_or_effective_date": "Current program page",
        "verified_date": "2026-09-19",
        "scope_limit": "Use the current exact NOA; a dated checklist or old NOA is not enough."
      },
      {
        "record_id": "J28",
        "compliance_path": "Miami-Dade Product Control",
        "requirement_topic": "Expiration dates",
        "what_the_source_says": "Current garage-door NOA lists display product descriptions and expiration dates.",
        "authority_type": "County product-approval database",
        "issuing_body": "Miami-Dade County Product Control",
        "source_document": "Product Control Search — current garage-door NOA examples",
        "source_locator": "NOA list",
        "source_url": "https://www.miamidade.gov/building/pc-result_detail_app.asp?app_alias=101895",
        "edition_or_effective_date": "Current records accessed 2026-09-19",
        "verified_date": "2026-09-19",
        "scope_limit": "An example NOA does not establish another product’s approval."
      },
      {
        "record_id": "J29",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Current code edition",
        "what_the_source_says": "WPI-1 applications starting April 1, 2026 must be certified to the 2024 IRC or 2024 IBC.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Adopted Building Codes",
        "source_locator": "Building Code",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_effective_date": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "Applies to the TDI/TWIA program, not every Texas project."
      },
      {
        "record_id": "J30",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Insurance eligibility",
        "what_the_source_says": "Construction must be certified to be eligible for TWIA windstorm coverage.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Adopted Building Codes",
        "source_locator": "Building Code",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_effective_date": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "Program eligibility is separate from an ordinary local permit."
      },
      {
        "record_id": "J31",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Site-specific wind speed",
        "what_the_source_says": "TDI says required wind speed must be determined for each structure based on location.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Adopted Building Codes",
        "source_locator": "Wind Speeds",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_effective_date": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "A county-wide generic speed is not a substitute for the project determination."
      },
      {
        "record_id": "J32",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Designated areas",
        "what_the_source_says": "TDI says the designated catastrophe areas did not change with the 2026 code adoption.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Adopted Building Codes",
        "source_locator": "Designated Catastrophe Areas",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_effective_date": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "Check the official map and the special Harris County description."
      },
      {
        "record_id": "J33",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Wind-borne-debris coverage",
        "what_the_source_says": "TDI says most designated catastrophe areas are now in the wind-borne-debris region and points to the 2024 codes.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Adopted Building Codes",
        "source_locator": "Windborne Debris Protection",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_effective_date": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "Exact project location and code criteria control."
      },
      {
        "record_id": "J34",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Effective-date confirmation",
        "what_the_source_says": "TDI’s general information table lists the 2024 IBC/IRC effective from April 1, 2026.",
        "authority_type": "State windstorm-program requirement",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Windstorm Inspection Program — General Information",
        "source_locator": "Code/effective-date table",
        "source_url": "https://tdi.texas.gov/WIND/geninfo.html",
        "edition_or_effective_date": "2024 IBC/IRC effective 2026-04-01",
        "verified_date": "2026-09-19",
        "scope_limit": "Program-specific."
      },
      {
        "record_id": "J35",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Legacy FAQ caveat",
        "what_the_source_says": "TDI’s product-evaluation FAQ was last updated before the April 2026 code transition and cites older test-standard editions in places.",
        "authority_type": "State program technical guidance",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Frequently Asked Questions Regarding Product Evaluations",
        "source_locator": "Page update date and Garage Doors section",
        "source_url": "https://www.tdi.texas.gov/wind/faqprodeval.html",
        "edition_or_effective_date": "Page last updated 2025-07-21",
        "verified_date": "2026-09-19",
        "scope_limit": "Use the current adopted-code page and project instructions when the pages differ."
      },
      {
        "record_id": "J36",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Product label evidence",
        "what_the_source_says": "The TDI FAQ identifies product/manufacturer, series/model, and design-pressure information, with impact/cyclic information when applicable.",
        "authority_type": "State program technical guidance",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Frequently Asked Questions Regarding Product Evaluations",
        "source_locator": "Label and Garage Doors sections",
        "source_url": "https://www.tdi.texas.gov/wind/faqprodeval.html",
        "edition_or_effective_date": "Page last updated 2025-07-21",
        "verified_date": "2026-09-19",
        "scope_limit": "Treat as program guidance with the legacy-page caveat."
      },
      {
        "record_id": "J37",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Unlisted products",
        "what_the_source_says": "The TDI FAQ explains that absence from its index does not necessarily mean rejection; an appointed qualified inspector may obtain evidence.",
        "authority_type": "State program technical guidance",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Frequently Asked Questions Regarding Product Evaluations",
        "source_locator": "Product-evaluation questions",
        "source_url": "https://www.tdi.texas.gov/wind/faqprodeval.html",
        "edition_or_effective_date": "Page last updated 2025-07-21",
        "verified_date": "2026-09-19",
        "scope_limit": "The project still needs accepted evidence and certification."
      },
      {
        "record_id": "J38",
        "compliance_path": "Texas TDI/TWIA windstorm program",
        "requirement_topic": "Third-party report links",
        "what_the_source_says": "TDI states that posting a link to a third-party report does not mean the report proves code compliance.",
        "authority_type": "State program disclaimer",
        "issuing_body": "Texas Department of Insurance",
        "source_document": "Product Evaluations",
        "source_locator": "Third-party weblinks disclaimer",
        "source_url": "https://tdi.texas.gov/wind/prod/index.html",
        "edition_or_effective_date": "Page last updated 2025-06-13",
        "verified_date": "2026-09-19",
        "scope_limit": "Match the exact product, configuration, code, installation, and project."
      },
      {
        "record_id": "J39",
        "compliance_path": "Cross-jurisdiction evidence rule",
        "requirement_topic": "Unknown versus zero",
        "what_the_source_says": "A missing label, report, field, or approval is an evidence gap; it is not proof of zero capacity or automatic compliance.",
        "authority_type": "Uptime editorial rule derived from source hierarchy",
        "issuing_body": "DASMA",
        "source_document": "TDS 181 — General Code Inspection Guidelines for Wind Load",
        "source_locator": "Label-alone warning and inspection framework",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "edition_or_effective_date": "Rev. 6/25",
        "verified_date": "2026-09-19",
        "scope_limit": "Resolve unknowns with the appropriate manufacturer, design professional, AHJ, or program."
      }
    ],
    "document_register": [
      {
        "document_id": "DOC01",
        "title_as_published": "International Building Code overview",
        "publisher": "International Code Council",
        "authority_type": "Model-code publisher",
        "revision_or_edition": "Current overview",
        "question_it_answers": "How does the IBC become enforceable?",
        "url": "https://www.iccsafe.org/products-and-services/i-codes/ibc/",
        "verified_date": "2026-09-19",
        "scope_note": "Adoption and local amendments control."
      },
      {
        "document_id": "DOC02",
        "title_as_published": "2024 International Building Code, Chapter 17 — Special Inspections and Tests",
        "publisher": "International Code Council",
        "authority_type": "Official model-code text",
        "revision_or_edition": "2024 IBC",
        "question_it_answers": "What test load, door test methods, and label fields does the model code state?",
        "url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Use the locally adopted edition."
      },
      {
        "document_id": "DOC03",
        "title_as_published": "ASCE/SEI 7-22",
        "publisher": "ASCE",
        "authority_type": "Official standard-publisher overview",
        "revision_or_edition": "2022 edition",
        "question_it_answers": "What current structural loading standard is used by model codes?",
        "url": "https://www.asce.org/publications-and-news/codes-and-standards/asce-sei-7-22",
        "verified_date": "2026-09-19",
        "scope_note": "Full standard not reproduced."
      },
      {
        "document_id": "DOC04",
        "title_as_published": "About the ASCE Hazard Tool",
        "publisher": "ASCE",
        "authority_type": "Official tool documentation",
        "revision_or_edition": "ASCE 7-10/7-16/7-22",
        "question_it_answers": "Where can site-specific hazard parameters be obtained?",
        "url": "https://www.asce.org/publications-and-news/asce-hazard-tool/about",
        "verified_date": "2026-09-19",
        "scope_note": "Does not approve a door."
      },
      {
        "document_id": "DOC05",
        "title_as_published": "DASMA Standards",
        "publisher": "DASMA",
        "authority_type": "Standards index",
        "revision_or_edition": "Current index",
        "question_it_answers": "Which DASMA standards and editions are published?",
        "url": "https://www.dasma.com/dasma-standards/",
        "verified_date": "2026-09-19",
        "scope_note": "Voluntary unless adopted or specified."
      },
      {
        "document_id": "DOC06",
        "title_as_published": "ANSI/DASMA 108-2017 — Standard Method for Testing Sectional Garage Doors and Rolling Doors",
        "publisher": "DASMA",
        "authority_type": "ANSI-approved standard",
        "revision_or_edition": "2017",
        "question_it_answers": "What standard addresses uniform static air-pressure testing?",
        "url": "https://www.dasma.com/dasma-standards/",
        "verified_date": "2026-09-19",
        "scope_note": "Use the exact published standard and code-referenced edition."
      },
      {
        "document_id": "DOC07",
        "title_as_published": "ANSI/DASMA 115-2017 — Standard Method for Testing Sectional Garage Doors",
        "publisher": "DASMA",
        "authority_type": "ANSI-approved standard",
        "revision_or_edition": "2017",
        "question_it_answers": "What standard addresses missile impact and cyclic pressure for its stated scope?",
        "url": "https://www.dasma.com/dasma-standards/",
        "verified_date": "2026-09-19",
        "scope_note": "Do not infer project applicability from the title alone."
      },
      {
        "document_id": "DOC08",
        "title_as_published": "Technical Data Sheets",
        "publisher": "DASMA",
        "authority_type": "Technical-guidance index",
        "revision_or_edition": "Current index",
        "question_it_answers": "Which public TDS documents exist and what is their scope?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "TDS documents do not replace manufacturer instructions or local rules."
      },
      {
        "document_id": "DOC09",
        "title_as_published": "TDS 155v — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-16",
        "publisher": "DASMA",
        "authority_type": "Technical guide",
        "revision_or_edition": "Rev. 4/26",
        "question_it_answers": "What selected ASCE 7-16 pressures appear in the published guide?",
        "url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS155v.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Use within printed assumptions."
      },
      {
        "document_id": "DOC10",
        "title_as_published": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "publisher": "DASMA",
        "authority_type": "Technical guide",
        "revision_or_edition": "Rev. 1/26",
        "question_it_answers": "What selected ASCE 7-22 pressures and multipliers appear in the published guide?",
        "url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Use within printed assumptions."
      },
      {
        "document_id": "DOC11",
        "title_as_published": "TDS 161 — Connecting Garage Door Jambs to Building Framing",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How does jamb attachment enter the load path?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use exact project substrate, loads, and manufacturer details."
      },
      {
        "document_id": "DOC12",
        "title_as_published": "TDS 168 — Wind Loads on Garage Doors: FAQ",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Rev. 3/26",
        "question_it_answers": "Who supplies project inputs and how are common terms distinguished?",
        "url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "FAQ only; project documents control."
      },
      {
        "document_id": "DOC13",
        "title_as_published": "TDS 172 — Garage Door Labels",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "What label types exist?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use exact code/program requirements."
      },
      {
        "document_id": "DOC14",
        "title_as_published": "TDS 174 — Building Occupant: Checking a Garage Door for Damage",
        "publisher": "DASMA",
        "authority_type": "Safety guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "What may an occupant safely observe after damage?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Visual observation only."
      },
      {
        "document_id": "DOC15",
        "title_as_published": "TDS 175 — Post-High Wind Event Door Operation by a Trained Door Systems Technician",
        "publisher": "DASMA",
        "authority_type": "Safety guidance",
        "revision_or_edition": "Current PDF",
        "question_it_answers": "What should a trained technician consider after a high-wind event?",
        "url": "https://www.dasma.com/wp-content/uploads/2022/12/TDS175.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "No public repair procedure is derived from it."
      },
      {
        "document_id": "DOC16",
        "title_as_published": "TDS 177 — Application of Kd Factor to Garage Door Wind Load Determination Using ASCE 7",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How is wind directionality treated?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use governing ASCE edition."
      },
      {
        "document_id": "DOC17",
        "title_as_published": "TDS 178 — Garage Door Wind Load Determination: Effective Wind Area",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Rev. 10/22",
        "question_it_answers": "What effective wind area applies to a typical single-unit door?",
        "url": "https://www.dasma.com/wp-content/uploads/2022/10/TDS178.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Complex assemblies require separate treatment."
      },
      {
        "document_id": "DOC18",
        "title_as_published": "TDS 180 — Wind Load Ratings for Non-Tested Garage Door and Rolling Door Sizes",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Reaffirmed 06/20",
        "question_it_answers": "How can size affect rating and what evidence is needed for untested sizes?",
        "url": "https://www.dasma.com/wp-content/uploads/pubs/TechDataSheets/CommercialResidential/TDS180.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Does not create a project rating."
      },
      {
        "document_id": "DOC19",
        "title_as_published": "TDS 181 — General Code Inspection Guidelines for Wind Load",
        "publisher": "DASMA",
        "authority_type": "Inspection guidance",
        "revision_or_edition": "Rev. 6/25",
        "question_it_answers": "What should be compared between the label, drawing, and installed door?",
        "url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Not an engineering approval."
      },
      {
        "document_id": "DOC20",
        "title_as_published": "TDS 183 — Garage Door Component Substitution",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "Why can component substitutions break the evidence chain?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Exact manufacturer acceptance controls."
      },
      {
        "document_id": "DOC21",
        "title_as_published": "TDS 193 — Wind Exposure Categories",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Rev. 1/22",
        "question_it_answers": "How are Exposure B, C, and D described and who determines them?",
        "url": "https://www.dasma.com/wp-content/uploads/2022/03/TDS193.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Project-specific determination."
      },
      {
        "document_id": "DOC22",
        "title_as_published": "TDS 194 — PSF versus MPH in Door Specifications",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current PDF",
        "question_it_answers": "Why is mph alone not a door pressure rating?",
        "url": "https://www.dasma.com/wp-content/uploads/2022/08/TDS194.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Preserve project pressure and basis."
      },
      {
        "document_id": "DOC23",
        "title_as_published": "TDS 1502 — The International Residential Code and Wind Load Labels",
        "publisher": "DASMA",
        "authority_type": "Code guidance",
        "revision_or_edition": "Rev. 6/24",
        "question_it_answers": "What does DASMA say about job-specific ratings and labels?",
        "url": "https://www.dasma.com/wp-content/uploads/2025/01/TDS-1502.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Primarily residential scope."
      },
      {
        "document_id": "DOC24",
        "title_as_published": "TDS 251 — Architects and Designers Should Understand Loads Exerted by Overhead Coiling Doors",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "Why do building-side reactions matter for rolling doors?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use manufacturer reactions and project structural design."
      },
      {
        "document_id": "DOC25",
        "title_as_published": "TDS 279 — Rolling Door Operation Under Wind Load Conditions",
        "publisher": "DASMA",
        "authority_type": "Operational guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How does wind affect rolling-door operation?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Separate from static closed-door rating."
      },
      {
        "document_id": "DOC26",
        "title_as_published": "TDS 281 — Rolling Door Wind Load Determination: Effective Wind Area",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How is effective wind area discussed for rolling doors?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use exact product and standard scope."
      },
      {
        "document_id": "DOC27",
        "title_as_published": "TDS 291 — Rolling Doors and High Wind Events",
        "publisher": "DASMA",
        "authority_type": "Safety guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "What high-wind issues apply to rolling doors?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "No improvised operation or repair instruction."
      },
      {
        "document_id": "DOC28",
        "title_as_published": "TDS 292 — Vehicular Access Door Interface with Building Framing",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How does the door interface with supporting construction?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Project structural design controls."
      },
      {
        "document_id": "DOC29",
        "title_as_published": "TDS 293 — Architects and Designers Should Understand Loads Exerted by Rolling Sheet Doors",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "What reactions can rolling sheet doors impose?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Use exact manufacturer data."
      },
      {
        "document_id": "DOC30",
        "title_as_published": "TDS 456 — High Performance Door Operation Under Wind Load Conditions",
        "publisher": "DASMA",
        "authority_type": "Operational guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "How can wind affect high-performance-door operation?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Not a static-rating standard."
      },
      {
        "document_id": "DOC31",
        "title_as_published": "TDS 459 — Wind on High Performance Doors: Frequently Asked Questions",
        "publisher": "DASMA",
        "authority_type": "Technical guidance",
        "revision_or_edition": "Current index entry",
        "question_it_answers": "What wind questions arise for high-performance doors?",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "verified_date": "2026-09-19",
        "scope_note": "Product-specific instructions control."
      },
      {
        "document_id": "DOC32",
        "title_as_published": "Tech Corner — Understanding operational wind load",
        "publisher": "DASMA / Door + Access Systems Magazine",
        "authority_type": "Trade technical article",
        "revision_or_edition": "Summer 2025",
        "question_it_answers": "Is there a consensus operational-wind test method?",
        "url": "https://mydigimag.rrd.com/article/Tech+Corner/4995460/847956/article.html",
        "verified_date": "2026-09-19",
        "scope_note": "Reports work in progress, not a standard."
      },
      {
        "document_id": "DOC33",
        "title_as_published": "Florida Building Commission home page",
        "publisher": "Florida Building Commission",
        "authority_type": "State code authority",
        "revision_or_edition": "8th Edition (2023)",
        "question_it_answers": "What Florida code edition is currently effective?",
        "url": "https://www.floridabuilding.org/",
        "verified_date": "2026-09-19",
        "scope_note": "Check supplements and future update notices."
      },
      {
        "document_id": "DOC34",
        "title_as_published": "Florida Product Approval Search",
        "publisher": "Florida Building Commission",
        "authority_type": "State product-approval database",
        "revision_or_edition": "2023 Florida Building Code",
        "question_it_answers": "What approval, HVHZ, impact, and ±DP fields are searchable?",
        "url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "verified_date": "2026-09-19",
        "scope_note": "Open exact record and limits."
      },
      {
        "document_id": "DOC35",
        "title_as_published": "Materials related to the 2026 Florida Building Code update",
        "publisher": "Florida Building Commission",
        "authority_type": "State code-development material",
        "revision_or_edition": "2026 update process",
        "question_it_answers": "What future code work is underway?",
        "url": "https://www.floridabuilding.org/",
        "verified_date": "2026-09-19",
        "scope_note": "Do not assert an effective date until officially adopted."
      },
      {
        "document_id": "DOC36",
        "title_as_published": "Product Approval",
        "publisher": "Miami-Dade County Product Control",
        "authority_type": "County product-approval program",
        "revision_or_edition": "Current page",
        "question_it_answers": "How does Miami-Dade describe its product approval program?",
        "url": "https://www.miamidade.gov/global/economy/building/product-approval.page",
        "verified_date": "2026-09-19",
        "scope_note": "Use exact current NOA."
      },
      {
        "document_id": "DOC37",
        "title_as_published": "Product Control Search",
        "publisher": "Miami-Dade County Product Control",
        "authority_type": "County product-approval database",
        "revision_or_edition": "Current search",
        "question_it_answers": "Where are current NOAs and expirations found?",
        "url": "https://www.miamidade.gov/building/pc-search_app.asp",
        "verified_date": "2026-09-19",
        "scope_note": "Search output is product-specific."
      },
      {
        "document_id": "DOC38",
        "title_as_published": "Product Approval Forms",
        "publisher": "Miami-Dade County Product Control",
        "authority_type": "County program forms",
        "revision_or_edition": "Current forms page",
        "question_it_answers": "Which application forms and checklists are currently posted?",
        "url": "https://www.miamidade.gov/global/economy/building/product-approval-forms.page",
        "verified_date": "2026-09-19",
        "scope_note": "A dated form is not a complete statement of current project requirements."
      },
      {
        "document_id": "DOC39",
        "title_as_published": "Adopted Building Codes",
        "publisher": "Texas Department of Insurance",
        "authority_type": "State windstorm-program authority",
        "revision_or_edition": "2024 IBC/IRC effective 2026-04-01",
        "question_it_answers": "What code edition and location rules now govern WPI-1 applications?",
        "url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "verified_date": "2026-09-19",
        "scope_note": "Program-specific."
      },
      {
        "document_id": "DOC40",
        "title_as_published": "Windstorm Inspection Program — General Information",
        "publisher": "Texas Department of Insurance",
        "authority_type": "State windstorm-program authority",
        "revision_or_edition": "Updated 2026-04-02",
        "question_it_answers": "What are the code effective dates?",
        "url": "https://tdi.texas.gov/WIND/geninfo.html",
        "verified_date": "2026-09-19",
        "scope_note": "Program-specific."
      },
      {
        "document_id": "DOC41",
        "title_as_published": "Frequently Asked Questions Regarding Product Evaluations",
        "publisher": "Texas Department of Insurance",
        "authority_type": "State technical guidance",
        "revision_or_edition": "Last updated 2025-07-21",
        "question_it_answers": "What product-evidence and label guidance does TDI publish?",
        "url": "https://www.tdi.texas.gov/wind/faqprodeval.html",
        "verified_date": "2026-09-19",
        "scope_note": "Parts predate the April 2026 code transition."
      },
      {
        "document_id": "DOC42",
        "title_as_published": "Product Evaluations",
        "publisher": "Texas Department of Insurance",
        "authority_type": "State product-evaluation index",
        "revision_or_edition": "Last updated 2025-06-13",
        "question_it_answers": "What does TDI say about third-party reports?",
        "url": "https://tdi.texas.gov/wind/prod/index.html",
        "verified_date": "2026-09-19",
        "scope_note": "A linked report is not automatic proof of compliance."
      }
    ],
    "verification_checklist": [
      {
        "step": 1,
        "stage": "Before you buy",
        "what_to_check": "Obtain the project-required positive and negative design pressures in psf, with the pressure basis identified.",
        "why_it_matters": "A bare wind speed or unsigned pressure does not establish the door requirement.",
        "governing_source": "Project design criteria; DASMA TDS 168 and TDS 193",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "The project design professional/AHJ establishes the project basis; a supplier may select a product from confirmed inputs."
      },
      {
        "step": 2,
        "stage": "Before you buy",
        "what_to_check": "Confirm the adopted code edition, ASCE 7 edition, and local amendments.",
        "why_it_matters": "The newest model-code edition does not automatically govern.",
        "governing_source": "ICC IBC overview; ASCE Hazard Tool",
        "source_url": "https://www.iccsafe.org/products-and-services/i-codes/ibc/",
        "verified_date": "2026-09-19",
        "scope_limit": "Record the actual project jurisdiction and edition."
      },
      {
        "step": 3,
        "stage": "Before you buy",
        "what_to_check": "Confirm the exposure category and who determined it.",
        "why_it_matters": "The published guide multipliers show that exposure can materially change pressure.",
        "governing_source": "DASMA TDS 193; TDS 155y",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/03/TDS193.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Do not assign exposure from a quick visual guess or a supplier preference."
      },
      {
        "step": 4,
        "stage": "Before you buy",
        "what_to_check": "Confirm the opening width, height, wall location, mean roof height, enclosure basis, and any effective-wind-area assumption used.",
        "why_it_matters": "These inputs can change the pressure or whether a published guide applies.",
        "governing_source": "DASMA TDS 155y; TDS 168; TDS 178",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Complex assemblies and openings outside guide limits require project-specific work."
      },
      {
        "step": 5,
        "stage": "Before you buy",
        "what_to_check": "Ask whether wind-borne-debris impact evidence is required for this opening.",
        "why_it_matters": "Static pressure resistance and impact/cyclic resistance are separate evidence questions.",
        "governing_source": "2024 IBC §1709.5.3; DASMA standards index",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_limit": "Apply the exact adopted code, opening type, location, and regional program."
      },
      {
        "step": 6,
        "stage": "Before you buy",
        "what_to_check": "For Florida work, search the exact current Florida Product Approval record and its limits of use.",
        "why_it_matters": "The state database separates HVHZ, outside-HVHZ, impact, and positive/negative DP.",
        "governing_source": "Florida Product Approval Search",
        "source_url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "verified_date": "2026-09-19",
        "scope_limit": "Match model, revision, size, options, instructions, and limits."
      },
      {
        "step": 7,
        "stage": "Before you buy",
        "what_to_check": "For a Miami-Dade Product Control project, find the exact current NOA and expiration.",
        "why_it_matters": "NOAs are product/configuration-specific and expire.",
        "governing_source": "Miami-Dade Product Control Search",
        "source_url": "https://www.miamidade.gov/global/economy/building/product-approval.page",
        "verified_date": "2026-09-19",
        "scope_limit": "Do not rely on an expired or merely similar NOA."
      },
      {
        "step": 8,
        "stage": "Before you buy",
        "what_to_check": "For TDI/TWIA work, confirm the current 2024-code certification path and official project location.",
        "why_it_matters": "The 2024 IRC/IBC path applies to WPI-1 applications starting April 1, 2026.",
        "governing_source": "TDI Adopted Building Codes",
        "source_url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "verified_date": "2026-09-19",
        "scope_limit": "The program does not apply to every Texas project."
      },
      {
        "step": 9,
        "stage": "On the quote",
        "what_to_check": "Confirm the quoted rating covers the exact opening size, model, configuration, reinforcement, glazing, and operation.",
        "why_it_matters": "A model-family name alone does not establish one rating for every size and option.",
        "governing_source": "DASMA TDS 180; manufacturer evidence",
        "source_url": "https://www.dasma.com/wp-content/uploads/pubs/TechDataSheets/CommercialResidential/TDS180.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Manufacturer-stated evidence is configuration-specific."
      },
      {
        "step": 10,
        "stage": "On the quote",
        "what_to_check": "Request the exact wind-load installation drawing and revision referenced by the door evidence.",
        "why_it_matters": "The drawing carries the configuration and attachment details behind the rating.",
        "governing_source": "2024 IBC §1709.5.2.1; DASMA TDS 181",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_limit": "Do not substitute a similar model’s drawing."
      },
      {
        "step": 11,
        "stage": "On the quote",
        "what_to_check": "Identify who will verify the jambs, header, wall, and supporting structure for the manufacturer’s reactions.",
        "why_it_matters": "The door rating does not prove the building-side support can resist the delivered loads.",
        "governing_source": "DASMA TDS 168 Q16; TDS 181 note 2",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Project drawings and accepted structural details control."
      },
      {
        "step": 12,
        "stage": "At delivery",
        "what_to_check": "Read and photograph the permanent label from a safe position.",
        "why_it_matters": "The 2024 IBC model-code provision lists manufacturer, model/series, ±DP, drawing reference, and test standard.",
        "governing_source": "2024 IBC §1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_limit": "Additional program fields may apply."
      },
      {
        "step": 13,
        "stage": "At delivery",
        "what_to_check": "Reject a submittal that gives only an mph marketing claim without project ±PSF and comparable pressure basis.",
        "why_it_matters": "Wind speed is an input; mph alone does not establish the door’s project rating.",
        "governing_source": "DASMA TDS 194",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/08/TDS194.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "A manufacturer may use wind-speed language, but the evidence chain still needs pressure and configuration."
      },
      {
        "step": 14,
        "stage": "At installation",
        "what_to_check": "Compare reinforcement location, size, quantity, and fasteners with the exact drawing.",
        "why_it_matters": "The rated assembly depends on its documented configuration.",
        "governing_source": "DASMA TDS 181 item 6",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Do not add, remove, move, or substitute components without accepted documentation."
      },
      {
        "step": 15,
        "stage": "At installation",
        "what_to_check": "Compare stiles, hinges, rollers, retainers, tracks/guides, brackets, and spacing with the drawing.",
        "why_it_matters": "These components transfer pressure through the door assembly.",
        "governing_source": "DASMA TDS 181 items 7–12",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Observation is not permission to adjust stored-energy components."
      },
      {
        "step": 16,
        "stage": "At installation",
        "what_to_check": "Compare jamb-to-structure anchors, substrate, quantity, spacing, embedment, and edge distance with the accepted detail.",
        "why_it_matters": "This is the load path from the door into the building.",
        "governing_source": "DASMA TDS 181 item 15; TDS 161",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "No generic anchor schedule is supplied by this dataset."
      },
      {
        "step": 17,
        "stage": "At installation",
        "what_to_check": "Confirm required locks, wind posts, windlocks, and other setup-dependent components are present and match.",
        "why_it_matters": "Some rated configurations depend on those components.",
        "governing_source": "DASMA TDS 181 items 10 and 14",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Exact drawing and manufacturer instructions control."
      },
      {
        "step": 18,
        "stage": "At installation",
        "what_to_check": "If glazed, confirm the glazing type, location, and extent match the accepted evidence.",
        "why_it_matters": "Glazing can change impact evidence and the approved configuration even when the project pressure stays the same.",
        "governing_source": "DASMA TDS 168 Q8; TDS 181 item 13",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Use the exact approval/report."
      },
      {
        "step": 19,
        "stage": "At closeout",
        "what_to_check": "Retain the pressure schedule, label photo, exact drawing, reports/approvals, RFIs, inspection records, and AHJ/program acceptance.",
        "why_it_matters": "Future replacement, insurance, audit, and repair decisions depend on the evidence chain.",
        "governing_source": "Uptime editorial framework from cited sources",
        "source_url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "Retention periods may be set by law, contract, insurer, or owner policy."
      },
      {
        "step": 20,
        "stage": "After a high-wind event or visible damage",
        "what_to_check": "From a safe position, look for visible damage and keep clear of springs, cables, brackets, and other stored-energy parts; stop using the door when damage, binding, loose parts, or an unsafe condition is present and obtain a trained evaluation.",
        "why_it_matters": "DASMA separates occupant observation from technician-level post-event operation and repair.",
        "governing_source": "DASMA TDS 174; TDS 175; TDS 181 warning",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/12/TDS175.pdf",
        "verified_date": "2026-09-19",
        "scope_limit": "This is a stop/use-escalation rule, not a repair procedure or a claim that every undamaged door requires a technician after every storm."
      }
    ],
    "terminology_crosswalk": [
      {
        "term": "Project-required design pressure",
        "what_it_means_here": "The positive and negative pressure the opening must resist under the project design basis.",
        "often_confused_with": "Basic wind speed or a product marketing rating",
        "source": "Project design criteria; DASMA TDS 168",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Record the pressure basis and units."
      },
      {
        "term": "Door design-pressure rating",
        "what_it_means_here": "The manufacturer-stated positive and negative rating for the exact documented assembly.",
        "often_confused_with": "Test pressure or a universal model-family rating",
        "source": "2024 IBC §1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Does not prove project installation or approval."
      },
      {
        "term": "Positive design pressure",
        "what_it_means_here": "Pressure in the positive direction as defined by the project and product evidence.",
        "often_confused_with": "The only pressure that matters",
        "source": "2024 IBC §1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Both positive and negative values must be checked."
      },
      {
        "term": "Negative design pressure",
        "what_it_means_here": "The suction/outward-direction pressure, normally shown with a negative sign.",
        "often_confused_with": "A smaller or optional rating",
        "source": "2024 IBC §1709.5.2.1",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Preserve sign and compare magnitude consistently."
      },
      {
        "term": "Test pressure",
        "what_it_means_here": "The pressure imposed during a stated test procedure; the 2024 IBC model provision uses 1.5 times design pressure for 10 seconds.",
        "often_confused_with": "A higher usable door design rating",
        "source": "2024 IBC §1709.5.2",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Do not label it as allowable design pressure."
      },
      {
        "term": "Allowable stress design (ASD)",
        "what_it_means_here": "A load basis used for allowable-stress comparison and many product ratings.",
        "often_confused_with": "Ultimate/strength basis",
        "source": "DASMA TDS 168 Q21",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Convert only when the source value and governing method permit it."
      },
      {
        "term": "Ultimate/strength design basis",
        "what_it_means_here": "A different load basis used by ASCE 7 wind maps and structural design.",
        "often_confused_with": "The number to put directly on every door order",
        "source": "DASMA TDS 168 Q21",
        "source_url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Do not compare with an ASD rating until bases are reconciled."
      },
      {
        "term": "Basic design wind speed",
        "what_it_means_here": "A site hazard input under a named ASCE 7 edition and risk category.",
        "often_confused_with": "A door rating in mph",
        "source": "ASCE Hazard Tool; DASMA TDS 194",
        "source_url": "https://www.asce.org/publications-and-news/asce-hazard-tool/about",
        "verified_date": "2026-09-19",
        "scope_note": "Wind speed alone does not produce one universal door pressure."
      },
      {
        "term": "Exposure category",
        "what_it_means_here": "A project classification describing terrain roughness and upwind conditions.",
        "often_confused_with": "A value a door dealer may casually choose",
        "source": "DASMA TDS 193",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/03/TDS193.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Determined for the actual project by the appropriate design/AHJ process."
      },
      {
        "term": "Effective wind area",
        "what_it_means_here": "The area used to determine external pressure coefficients; for a typical single-unit garage-door assembly, the overall door area.",
        "often_confused_with": "Always one section area or always width × height for every assembly",
        "source": "DASMA TDS 178",
        "source_url": "https://www.dasma.com/wp-content/uploads/2022/10/TDS178.pdf",
        "verified_date": "2026-09-19",
        "scope_note": "Complex or mulled assemblies require project-specific treatment."
      },
      {
        "term": "Impact resistant",
        "what_it_means_here": "Supported by accepted missile-impact and cyclic-pressure evidence under the applicable program.",
        "often_confused_with": "A high static PSF rating",
        "source": "DASMA standards index; adopted program documents",
        "source_url": "https://www.dasma.com/dasma-standards/",
        "verified_date": "2026-09-19",
        "scope_note": "Pressure and impact evidence are separate."
      },
      {
        "term": "Wind-load installation drawing",
        "what_it_means_here": "The exact manufacturer drawing that defines the rated configuration and attachment details.",
        "often_confused_with": "The permanent label",
        "source": "2024 IBC §1709.5.2.1; DASMA TDS 181",
        "source_url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "verified_date": "2026-09-19",
        "scope_note": "Use the exact revision referenced by the evidence."
      },
      {
        "term": "Operational wind load",
        "what_it_means_here": "A manufacturer- or project-defined measure of door operation while wind is acting on it.",
        "often_confused_with": "Closed-door static design-pressure rating",
        "source": "DASMA Tech Corner, Summer 2025",
        "source_url": "https://mydigimag.rrd.com/article/Tech+Corner/4995460/847956/article.html",
        "verified_date": "2026-09-19",
        "scope_note": "No consensus industry test standard was listed as published on the verification date."
      }
    ],
    "source_register": [
      {
        "source_id": "S01",
        "publisher": "International Code Council",
        "document": "International Building Code overview",
        "authority_type": "Model-code publisher",
        "url": "https://www.iccsafe.org/products-and-services/i-codes/ibc/",
        "edition_or_revision": "Current overview",
        "exact_locator": "Adoptions of the IBC",
        "scope_used": "Explains that the IBC is a model code adopted by governmental jurisdictions and may be amended.",
        "verified_date": "2026-09-19",
        "scope_limit": "The newest model-code edition does not automatically govern a project."
      },
      {
        "source_id": "S02",
        "publisher": "International Code Council",
        "document": "2024 International Building Code, Chapter 17",
        "authority_type": "Official model-code text",
        "url": "https://codes.iccsafe.org/content/IBC2024P1/chapter-17-special-inspections-and-tests",
        "edition_or_revision": "2024 IBC",
        "exact_locator": "§1709.5.2; §1709.5.2.1; §1709.5.3",
        "scope_used": "Door test pressure, test methods, permanent label fields, and model-code impact scope.",
        "verified_date": "2026-09-19",
        "scope_limit": "Use the edition and amendments adopted by the project jurisdiction."
      },
      {
        "source_id": "S03",
        "publisher": "American Society of Civil Engineers",
        "document": "ASCE/SEI 7-22",
        "authority_type": "Official standard-publisher overview",
        "url": "https://www.asce.org/publications-and-news/codes-and-standards/asce-sei-7-22",
        "edition_or_revision": "ASCE/SEI 7-22",
        "exact_locator": "Standard overview",
        "scope_used": "Identifies ASCE 7-22 as the current nationally used structural loading standard.",
        "verified_date": "2026-09-19",
        "scope_limit": "The full standard is copyrighted and was not reproduced."
      },
      {
        "source_id": "S04",
        "publisher": "American Society of Civil Engineers",
        "document": "About the ASCE Hazard Tool",
        "authority_type": "Official standard-publisher tool documentation",
        "url": "https://www.asce.org/publications-and-news/asce-hazard-tool/about",
        "edition_or_revision": "Supports ASCE 7-10, 7-16, and 7-22",
        "exact_locator": "Using the Tool; Data Sources; FAQ",
        "scope_used": "Site lookup, edition selection, wind and wind-borne-debris data.",
        "verified_date": "2026-09-19",
        "scope_limit": "The tool supplies hazard parameters; it does not approve a door assembly."
      },
      {
        "source_id": "S05",
        "publisher": "DASMA",
        "document": "DASMA Standards",
        "authority_type": "ANSI-accredited standards-development organization index",
        "url": "https://www.dasma.com/dasma-standards/",
        "edition_or_revision": "Current index",
        "exact_locator": "ANSI/DASMA 108-2017 and ANSI/DASMA 115-2017",
        "scope_used": "Published standard titles and editions.",
        "verified_date": "2026-09-19",
        "scope_limit": "A voluntary standard becomes enforceable only when adopted, incorporated, or specified."
      },
      {
        "source_id": "S06",
        "publisher": "DASMA",
        "document": "Technical Data Sheets",
        "authority_type": "Industry technical-guidance index",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "edition_or_revision": "Current index",
        "exact_locator": "TDS introduction and document list",
        "scope_used": "Current TDS inventory, preliminary-calculation warning, and document scope.",
        "verified_date": "2026-09-19",
        "scope_limit": "DASMA says TDS documents do not replace manufacturer instructions or local regulations."
      },
      {
        "source_id": "S07",
        "publisher": "DASMA",
        "document": "TDS 155v — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-16",
        "authority_type": "Industry technical guide",
        "url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS155v.pdf",
        "edition_or_revision": "Rev. 4/26; chart editions identified in PDF",
        "exact_locator": "Cover, general notes, pp. 3–10",
        "scope_used": "ASCE 7-16 chart values and assumptions used in the paired comparison.",
        "verified_date": "2026-09-19",
        "scope_limit": "Guide values apply only within the printed assumptions and bounds."
      },
      {
        "source_id": "S08",
        "publisher": "DASMA",
        "document": "TDS 155y — Garage Door and Commercial Door Wind Load Guide Based on ASCE 7-22 and the 2024 IBC",
        "authority_type": "Industry technical guide",
        "url": "https://www.dasma.com/wp-content/uploads/2026/03/TDS-155y.pdf",
        "edition_or_revision": "Rev. 1/26",
        "exact_locator": "General notes and pp. 3–10",
        "scope_used": "ASCE 7-22 chart values, multipliers, assumptions, 9.6-psf chart floor, and tornado note.",
        "verified_date": "2026-09-19",
        "scope_limit": "The 9.6-psf value is the minimum charted under this guide’s assumptions, not a universal project minimum."
      },
      {
        "source_id": "S09",
        "publisher": "DASMA",
        "document": "TDS 168 — Wind Loads on Garage Doors: FAQ",
        "authority_type": "Industry technical guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2026/06/TDS168-.pdf",
        "edition_or_revision": "Rev. 3/26",
        "exact_locator": "Questions 1–3, 8–9, 12, 15–21",
        "scope_used": "Pressure terminology, project roles, orientation, glazing, impact, weighted average, and load-basis cautions.",
        "verified_date": "2026-09-19",
        "scope_limit": "FAQ guidance does not replace the project code, design criteria, or manufacturer instructions."
      },
      {
        "source_id": "S10",
        "publisher": "DASMA",
        "document": "TDS 178 — Garage Door Wind Load Determination: Effective Wind Area",
        "authority_type": "Industry technical guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2022/10/TDS178.pdf",
        "edition_or_revision": "Rev. 10/22",
        "exact_locator": "Background and conclusion",
        "scope_used": "Effective-wind-area treatment for typical single-unit door assemblies and ASCE 7-16 wording change.",
        "verified_date": "2026-09-19",
        "scope_limit": "Complex or mulled assemblies require manufacturer or project-specific evaluation."
      },
      {
        "source_id": "S11",
        "publisher": "DASMA",
        "document": "TDS 180 — Wind Load Ratings for Non-Tested Garage Door and Rolling Door Sizes",
        "authority_type": "Industry technical guidance",
        "url": "https://www.dasma.com/wp-content/uploads/pubs/TechDataSheets/CommercialResidential/TDS180.pdf",
        "edition_or_revision": "Reaffirmed 06/20",
        "exact_locator": "Rating discussion and conclusion",
        "scope_used": "Why ratings can vary by size and why untested sizes require accepted analysis or testing.",
        "verified_date": "2026-09-19",
        "scope_limit": "Manufacturer or jurisdiction acceptance controls; the page does not establish a rating."
      },
      {
        "source_id": "S12",
        "publisher": "DASMA",
        "document": "TDS 181 — General Code Inspection Guidelines for Wind Load",
        "authority_type": "Industry inspection guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2025/08/TDS-181.pdf",
        "edition_or_revision": "Rev. 6/25",
        "exact_locator": "Opening notes and 15-item inspection list",
        "scope_used": "Label-alone warning, physical configuration checks, load-path items, and stored-energy safety boundary.",
        "verified_date": "2026-09-19",
        "scope_limit": "Visual verification is not an engineering calculation or permit approval."
      },
      {
        "source_id": "S13",
        "publisher": "DASMA",
        "document": "TDS 193 — Wind Exposure Categories",
        "authority_type": "Industry technical guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2022/03/TDS193.pdf",
        "edition_or_revision": "Rev. 1/22",
        "exact_locator": "Exposure definitions and conclusion",
        "scope_used": "Exposure B/C/D language, design-professional responsibility, and attributed ASCE commentary range.",
        "verified_date": "2026-09-19",
        "scope_limit": "Exposure must be determined for the actual project; the 60–80% statement is attributed commentary, not a Uptime estimate."
      },
      {
        "source_id": "S14",
        "publisher": "DASMA",
        "document": "TDS 194 — PSF versus MPH in Door Specifications",
        "authority_type": "Industry technical guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2022/08/TDS194.pdf",
        "edition_or_revision": "Current PDF accessed 2026-09-19",
        "exact_locator": "Entire sheet",
        "scope_used": "Explains why a door is specified by project pressure rather than an mph claim.",
        "verified_date": "2026-09-19",
        "scope_limit": "A manufacturer may market wind-speed language, but mph alone does not establish project compliance."
      },
      {
        "source_id": "S15",
        "publisher": "DASMA",
        "document": "TDS 1502 — The International Residential Code and Wind Load Labels",
        "authority_type": "Industry code guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2025/01/TDS-1502.pdf",
        "edition_or_revision": "Rev. 6/24",
        "exact_locator": "Questions on rating and labels",
        "scope_used": "Confirms not all doors are wind-rated and identifies job-specific rating/label concepts.",
        "verified_date": "2026-09-19",
        "scope_limit": "Primarily residential-code guidance; used only for generally applicable label/rating distinctions."
      },
      {
        "source_id": "S16",
        "publisher": "DASMA",
        "document": "TDS 174 — Building Occupant: Checking a Garage Door for Damage",
        "authority_type": "Industry safety guidance",
        "url": "https://www.dasma.com/technical-data-sheets/",
        "edition_or_revision": "Current index entry",
        "exact_locator": "TDS 174",
        "scope_used": "Safe visual observation boundary after damage.",
        "verified_date": "2026-09-19",
        "scope_limit": "Does not authorize repair or operation of damaged equipment."
      },
      {
        "source_id": "S17",
        "publisher": "DASMA",
        "document": "TDS 175 — Post-High Wind Event Door Operation by a Trained Door Systems Technician",
        "authority_type": "Industry safety guidance",
        "url": "https://www.dasma.com/wp-content/uploads/2022/12/TDS175.pdf",
        "edition_or_revision": "Current PDF accessed 2026-09-19",
        "exact_locator": "Entire sheet",
        "scope_used": "Technician-level post-event evaluation and operation scope.",
        "verified_date": "2026-09-19",
        "scope_limit": "Applies after observed damage or a severe event; it does not mean every door always requires a technician before any post-storm operation."
      },
      {
        "source_id": "S18",
        "publisher": "DASMA / Door + Access Systems Magazine",
        "document": "Tech Corner — Understanding operational wind load",
        "authority_type": "Trade-association technical article",
        "url": "https://mydigimag.rrd.com/article/Tech+Corner/4995460/847956/article.html",
        "edition_or_revision": "Summer 2025",
        "exact_locator": "Operational wind-load discussion",
        "scope_used": "Static versus operational performance and status of industry test-method development.",
        "verified_date": "2026-09-19",
        "scope_limit": "Reports committee work; it is not a published consensus test standard."
      },
      {
        "source_id": "S19",
        "publisher": "Florida Building Commission",
        "document": "Florida Building Commission home page",
        "authority_type": "State code authority",
        "url": "https://www.floridabuilding.org/",
        "edition_or_revision": "8th Edition (2023), effective 2023-12-31",
        "exact_locator": "Effective-date notice",
        "scope_used": "Current Florida Building Code edition and effective date.",
        "verified_date": "2026-09-19",
        "scope_limit": "The site also shows a 2026 update process; no unverified future effective date is asserted."
      },
      {
        "source_id": "S20",
        "publisher": "Florida Building Commission",
        "document": "Florida Product Approval Search",
        "authority_type": "State product-approval database",
        "url": "https://www.floridabuilding.org/pr/pr_app_srch.aspx",
        "edition_or_revision": "2023 Florida Building Code",
        "exact_locator": "Search fields",
        "scope_used": "Exact record fields: code version, HVHZ, outside-HVHZ, impact, and positive/negative design pressure.",
        "verified_date": "2026-09-19",
        "scope_limit": "A record must be matched to the exact model, revision, configuration, instructions, and limits of use."
      },
      {
        "source_id": "S21",
        "publisher": "Miami-Dade County Product Control",
        "document": "Product Approval and Product Control Search",
        "authority_type": "County product-approval program",
        "url": "https://www.miamidade.gov/global/economy/building/product-approval.page",
        "edition_or_revision": "Current program page",
        "exact_locator": "Product approval information and search access",
        "scope_used": "Current NOA search and product-specific approval workflow.",
        "verified_date": "2026-09-19",
        "scope_limit": "A dated checklist or expired NOA is not a substitute for the current exact NOA."
      },
      {
        "source_id": "S22",
        "publisher": "Miami-Dade County Product Control",
        "document": "Product Control Search — current garage-door NOA examples",
        "authority_type": "County product-approval database",
        "url": "https://www.miamidade.gov/building/pc-result_detail_app.asp?app_alias=101895",
        "edition_or_revision": "Current records accessed 2026-09-19",
        "exact_locator": "Applicant NOA list and expiration dates",
        "scope_used": "Shows that NOAs are product/configuration-specific and carry expiration dates.",
        "verified_date": "2026-09-19",
        "scope_limit": "Examples do not establish requirements for another manufacturer, model, size, or project."
      },
      {
        "source_id": "S23",
        "publisher": "Texas Department of Insurance",
        "document": "Adopted Building Codes",
        "authority_type": "State windstorm-program authority",
        "url": "https://tdi.texas.gov/wind/adopted-codes.html",
        "edition_or_revision": "2024 IBC/IRC for WPI-1 applications starting 2026-04-01",
        "exact_locator": "Building Code; Wind Speeds; Windborne Debris Protection",
        "scope_used": "Current program edition, location-specific wind speed, designated areas, and wind-borne-debris scope.",
        "verified_date": "2026-09-19",
        "scope_limit": "Applies to TDI/TWIA windstorm-program projects, not every Texas project."
      },
      {
        "source_id": "S24",
        "publisher": "Texas Department of Insurance",
        "document": "Frequently Asked Questions Regarding Product Evaluations",
        "authority_type": "State program technical guidance",
        "url": "https://www.tdi.texas.gov/wind/faqprodeval.html",
        "edition_or_revision": "Page last updated 2025-07-21",
        "exact_locator": "General; Exterior Doors; Garage Doors",
        "scope_used": "Product-label and evaluation evidence, with a legacy-page caveat.",
        "verified_date": "2026-09-19",
        "scope_limit": "Parts of the page predate the 2026 code transition and cite older standard editions; current adopted-code requirements control."
      },
      {
        "source_id": "S25",
        "publisher": "Texas Department of Insurance",
        "document": "Product Evaluations",
        "authority_type": "State program product-evaluation index",
        "url": "https://tdi.texas.gov/wind/prod/index.html",
        "edition_or_revision": "Page last updated 2025-06-13",
        "exact_locator": "Third-party weblinks disclaimer",
        "scope_used": "Explains that a third-party report link does not itself prove project compliance.",
        "verified_date": "2026-09-19",
        "scope_limit": "Exact product, configuration, code, installation, and project acceptance still must match."
      },
      {
        "source_id": "S26",
        "publisher": "Texas Department of Insurance",
        "document": "Windstorm Inspection Program — General Information",
        "authority_type": "State windstorm-program authority",
        "url": "https://tdi.texas.gov/WIND/geninfo.html",
        "edition_or_revision": "2024 IBC/IRC effective 2026-04-01",
        "exact_locator": "Code/effective-date table",
        "scope_used": "Current effective-date table for the program.",
        "verified_date": "2026-09-19",
        "scope_limit": "Program-specific."
      }
    ]
  }
}