  "dataset_name": "Dock Leveler Symptom Reference Matrix",
  "version": "1.2.0",
  "compiled_by": "Uptime Dock & Door Research",
  "publisher": "Uptime Dock & Door",
  "compiled_date": "2026-09-17",
  "verified_date": "2026-09-17",
  "coverage": "Selected manufacturer documents, not a geographically sampled equipment dataset; federal U.S. general-industry context only for the legal discussion.",
  "source_document_period": "2018-08-31/2026-08-06, including the historical comparison; month-only issue precision retained in records.",
  "description": "Source-linked symptom references with model conditions, manual locators, and separately labeled editorial reporting guidance. No fault-to-OSHA classification or failure-rate estimate.",
  "reuse_note": "No blanket reuse license is assigned. The compilation adds descriptions and organization; manufacturers retain rights in their manuals. No third-party manual or diagram is redistributed.",
  "missing_value_rule": "Empty means unknown/not supplied, not zero. Comparison zero denotes no separately matched heading.",
  "key_figures": [
    {
      "id": "F1",
      "label": "Source-linked matrix entries",
      "value": 140,
      "unit": "reference entries",
      "population": "Selected troubleshooting sections from five named manuals",
      "geography": "Not geographically sampled",
      "period": "Manual issue dates December2018–August2026; compiled 2026-09-17",
      "evidence_type": "Calculated",
      "formula": "42 + 24 + 26 + 27 + 21 = 140",
      "source": "dock-leveler-symptom-matrix.csv",
      "limitation": "Includes a duplicate, warning, design note and inspection prompt; not 140 distinct faults."
    },
    {
      "id": "F2",
      "label": "Mechanical historical/newer document entries",
      "value": {
        "2018": 34,
        "2026": 42
      },
      "unit": "numbered source entries",
      "evidence_type": "Calculated",
      "formula": "2018: 5+7+3+4+2+2+5+3+3=34; 2026: 6+7+5+7+6+4+4+3+0=42",
      "source": "dock-leveler-edition-changes.csv EC-01–EC-09",
      "limitation": "Different document families; not a change in failure frequency, field performance, or proof of applicable edition."
    },
    {
      "id": "F3",
      "label": "Hydraulic historical/newer document entries",
      "value": {
        "2018": 14,
        "2026": 24
      },
      "unit": "numbered source entries",
      "evidence_type": "Calculated",
      "formula": "2018: 6+1+3+4+0+0=14; 2026: 12+2+4+3+2+1=24",
      "source": "dock-leveler-edition-changes.csv EC-10–EC-15",
      "limitation": "Includes notes; descriptive comparison of two different manuals only."
    }
  ],
  "files": {
    "symptom_matrix": "dock-leveler-symptom-matrix.csv",
    "edition_changes": "dock-leveler-edition-changes.csv",
    "terminology_crosswalk": "dock-leveler-terminology-crosswalk.csv",
    "authority_gate": "dock-leveler-authority-gate.csv",
    "manual_index": "dock-leveler-manual-index.csv",
    "sources": "dock-leveler-sources.csv",
    "onpage_crosswalk": "dock-leveler-onpage-crosswalk.csv",
    "data_dictionary": "dock-leveler-data-dictionary.csv"
  },
  "data": {
    "symptom_matrix": [
      {
        "row_id": "DLT-001",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Foreign materials may be lodged between the side of the deck and the pit wall",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-002",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "The bumpers may be damaged or missing, allowing the truck to contact and hold the lip",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-003",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Equipment or goods may be parked on the dock leveler",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-004",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Low hydraulic oil in power unit",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-005",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "Three-phase power supply only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Incorrect motor rotation",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-006",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Relief valve is bypassing",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-007",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs, deck stays put",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor DOES start and run",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Pilot operated to close check valve will not close",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-008",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Deck hesitates before it starts to lift",
        "source_symptom_reference": "Deck will not begin to raise immediately when motor begins to run",
        "applicability_condition": "Usually occurs only after the deck cylinder hose has been replaced with a new hose that was not pre-filled with oil",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Air trapped in the deck lifting cylinder",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-009",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Total silence when you press the button",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor does not attempt to run, no sound is heard from motor, powerpack or control box",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "No power supply to control box",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-010",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Total silence when you press the button",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor does not attempt to run, no sound is heard from motor, powerpack or control box",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Thermal overload tripped open",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-011",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Total silence when you press the button",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor does not attempt to run, no sound is heard from motor, powerpack or control box",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty control box component, for example a fuse, touch button, contactor or transformer",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-012",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "The breaker trips every time",
        "source_symptom_reference": "Deck will not raise when touch button is operated. Motor attempts to run, but power supply breaker switch trips to off position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Supply branch circuit overloaded by other equipment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-013",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip does not swing all the way out",
        "source_symptom_reference": "Lip does not extend fully",
        "applicability_condition": "Stated for the case where oil level in the reservoir is NOT low",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Lip plate bent causing hinge to bind",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-014",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip does not swing all the way out",
        "source_symptom_reference": "Lip does not extend fully",
        "applicability_condition": "Stated for the case where oil level in the reservoir is NOT low",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Foreign material lodged in the lip hinge area",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-015",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip does not swing all the way out",
        "source_symptom_reference": "Lip does not extend fully",
        "applicability_condition": "Stated for the case where oil level in the reservoir is NOT low",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Relief valve is bypassing",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-016",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip drops back very slowly, worse in the cold",
        "source_symptom_reference": "Lip lowers slowly in normal temperatures and very slowly in extremely cold weather. Deck lowering speed is correct",
        "applicability_condition": "Deck lowering speed is correct; lip lowers slowly at normal temperature and very slowly in extreme cold.",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "The manual warns against a valve adjustment for this symptom; opening the needle valve can make the deck lower too fast and lock the velocity fuse",
        "record_kind": "manufacturer_warning",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-017",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip drops back very slowly, worse in the cold",
        "source_symptom_reference": "Lip lowers slowly in normal temperatures and very slowly in extremely cold weather. Deck lowering speed is correct",
        "applicability_condition": "Deck lowering speed is correct; lip lowers slowly at normal temperature and very slowly in extreme cold.",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Gravity lowers the lip; free movement at the full-length hinge is necessary",
        "record_kind": "design_note",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-018",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck comes down too fast or too slowly",
        "source_symptom_reference": "Deck lowering speed is too slow or too fast",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Lowering speed adjustment required",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 28; match the symptom heading and numbered entry where present",
        "printed_page": "28",
        "pdf_page": "28",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-019",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck climbs partway then quits while the motor keeps running",
        "source_symptom_reference": "Deck raises partially and stops. Motor continues to run and power unit makes more noise than normal",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Oil level in reservoir is low",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-020",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Deck raises more slowly than normal and level in reservoir is normal",
        "applicability_condition": "Stated for the case where reservoir level is normal",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Deck or damaged skirts dragging on side of pit",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-021",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Deck raises more slowly than normal and level in reservoir is normal",
        "applicability_condition": "Stated for the case where reservoir level is normal",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Pilot operated to close check valve will not close",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-022",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Deck raises more slowly than normal and level in reservoir is normal",
        "applicability_condition": "Stated for the case where reservoir level is normal",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty powerpack",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-023",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck is stuck up in the air",
        "source_symptom_reference": "Deck will not lower from fully raised position. Lip does lower",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "The fall-safe velocity fuse located at the bottom of the deck cylinder is in the locked or closed position",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-024",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck is stuck up in the air",
        "source_symptom_reference": "Deck will not lower from fully raised, lip extended position. Lip does lower",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "The fall-safe velocity fuse located at the bottom of the deck cylinder is in the locked or closed position",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 29; match the symptom heading and numbered entry where present",
        "printed_page": "29",
        "pdf_page": "29",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-025",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Hold-down mechanism is not releasing; the release chain or handle may be jammed or broken",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-026",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Foreign materials may be lodged between the side of the deck and the pit wall",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-027",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The bumpers may be damaged or missing, allowing the truck to contact and hold the lip",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-028",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lifting chain may be routed incorrectly",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-029",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Missing or broken spring(s)",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-030",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Main spring adjustment not adjusted properly",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-031",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Deck may be dragging on the side of the pit, slowing its movement",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-032",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Foreign material may be lodged between the side of the deck and the pit wall",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-033",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Side brush seals may be coming loose",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-034",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Insufficient lubrication at the front/rear hinges or the four arm lubrication points",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-035",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Someone is standing on the deck while the leveler is being operated",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-036",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The manual directs attention to the snubber chain without specifying a failed component",
        "record_kind": "inspection_prompt",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-037",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck comes up too slowly for the lip to flip out",
        "source_symptom_reference": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Lifting springs may require adjustment",
        "record_kind": "possible_cause",
        "source_note": "The manufacturer says to rule out the other listed causes before considering lift-spring adjustment.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-038",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip swings out then falls straight back",
        "source_symptom_reference": "The lip does not lock after fully extending",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip lock is not engaging; the spring may be broken or stretched, or the lock may have seized",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-039",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip swings out then falls straight back",
        "source_symptom_reference": "The lip does not lock after fully extending",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip actuator is bent or broken",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-040",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip swings out then falls straight back",
        "source_symptom_reference": "The lip does not lock after fully extending",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Foreign material is lodged in the lip lock mechanism",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-041",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip swings out then falls straight back",
        "source_symptom_reference": "The lip does not lock after fully extending",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Foreign object between the spools of the lip and the deck",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-042",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip swings out then falls straight back",
        "source_symptom_reference": "The lip does not lock after fully extending",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip spool is seizing, rusted or damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-043",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Foreign material in the pit may be blocking the mechanism",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-044",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Side safety skirts are damaged and jammed against the wall",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-045",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The dock strut is engaged",
        "record_kind": "possible_cause",
        "source_note": "Do not remove a support or enter the pit to test this possibility; report recent service history.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-046",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The ratchet assembly may be damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-047",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Weather seals, skirts or deck may be dragging against the pit wall",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-048",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lift springs are improperly adjusted; tension may have been mistakenly increased to troubleshoot another problem",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-049",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not walk down, or fights you",
        "source_symptom_reference": "The deck will not walk down or is difficult to walk down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The ratchet assembly may be damaged",
        "record_kind": "duplicate_source_entry",
        "source_note": "Repeated in the source table; matches DLT-046. Retained to make the source-entry count reproducible.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 26; match the symptom heading and numbered entry where present",
        "printed_page": "26",
        "pdf_page": "26",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-050",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The pull chain is stuck in the open position",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-051",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The ratchet pawl teeth are broken",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-052",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The ratchet assembly mounts are broken",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-053",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The ratchet pawl has a foreign object preventing it from locking into place",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-054",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Mis-adjusted auto collar",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-055",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck springs back up after being walked down",
        "source_symptom_reference": "The deck does not stay down: it springs back up after being walked down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "One or both springs damaged or missing in the ratchet assembly",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-056",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Damaged or missing dock bumpers allow the truck to park too close to the dock leveler",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-057",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Height difference between the dock and truck bed may be greater than recommended",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-058",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip actuator assembly may be damaged, causing the lip to extend too early in the cycle",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-059",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip actuator requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-060",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Cannot park the leveler with the truck still there",
        "source_symptom_reference": "The lip will not clear the rear of the truck when attendant attempts to park the dock while the truck is parked",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Damaged or missing dock bumpers allow the truck to park too close to the dock leveler",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-061",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Cannot park the leveler with the truck still there",
        "source_symptom_reference": "The lip will not clear the rear of the truck when attendant attempts to park the dock while the truck is parked",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Height difference between the dock and truck bed may be greater than recommended",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-062",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Cannot park the leveler with the truck still there",
        "source_symptom_reference": "The lip will not clear the rear of the truck when attendant attempts to park the dock while the truck is parked",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip actuator requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-063",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Cannot park the leveler with the truck still there",
        "source_symptom_reference": "The lip will not clear the rear of the truck when attendant attempts to park the dock while the truck is parked",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip crown is set too high",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-064",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip stays out after the truck pulls away",
        "source_symptom_reference": "The lip does not release or swing down when the truck departs",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip lock may have seized due to lack of lubrication, or due to foreign material in the pit",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-065",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip stays out after the truck pulls away",
        "source_symptom_reference": "The lip does not release or swing down when the truck departs",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "The lip lock may be held in the locked position by foreign material in the pit",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-066",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip stays out after the truck pulls away",
        "source_symptom_reference": "The lip does not release or swing down when the truck departs",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "No traffic has crossed the deck to break the lip lock",
        "record_kind": "possible_cause",
        "source_note": "This is not permission to put traffic on an unsupported or malfunctioning leveler.",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 27; match the symptom heading and numbered entry where present",
        "printed_page": "27",
        "pdf_page": "27",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-067",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "The blower motor may have failed or been mis-wired",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-068",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "The control station is not functioning properly",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-069",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "Optional equipment only",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Overload relay may have been tripped",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-070",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Air bag may have been damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-071",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Main power feed may be disconnected or a fuse may have blown",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-072",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Press the button and nothing lifts",
        "source_symptom_reference": "Deck will not raise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Blower intake may be blocked",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-073",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not come back down",
        "source_symptom_reference": "Deck will not lower",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Debris may have accumulated under the platform",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-074",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not come back down",
        "source_symptom_reference": "Deck will not lower",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Maintenance stand may still be engaged",
        "record_kind": "possible_cause",
        "source_note": "Do not remove a support or enter the pit to test this possibility; report recent service history.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-075",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck will not come back down",
        "source_symptom_reference": "Deck will not lower",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Blower intake may be blocked",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-076",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck lifts slowly",
        "source_symptom_reference": "Deck raises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Air bag may be damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-077",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck lifts slowly",
        "source_symptom_reference": "Deck raises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Cargo and other weight sources may be sitting on the deck",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-078",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck lifts slowly",
        "source_symptom_reference": "Deck raises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Blower intake may be blocked",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-079",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck lifts slowly",
        "source_symptom_reference": "Deck raises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Blower uncoupled from bag",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-080",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck lifts slowly",
        "source_symptom_reference": "Deck raises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Inadequate voltage",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-081",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip stays hanging down",
        "source_symptom_reference": "The lip will not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Debris may be in the lip hinge",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-082",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip stays hanging down",
        "source_symptom_reference": "The lip will not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Lip deployment mechanism may be damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-083",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip stays hanging down",
        "source_symptom_reference": "The lip will not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Damaged air bag",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-084",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip stays hanging down",
        "source_symptom_reference": "The lip will not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Blower uncoupled from bag",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-085",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip stays hanging down",
        "source_symptom_reference": "The lip will not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Incorrect voltage relative to blower motor voltage",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "45",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-086",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip will not fold back in",
        "source_symptom_reference": "The lip remains in the extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Lip may be bent or damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-087",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip will not fold back in",
        "source_symptom_reference": "The lip remains in the extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "The lip deployment mechanism may be damaged",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-088",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip will not fold back in",
        "source_symptom_reference": "The lip remains in the extended position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Debris may have collected in the lip hinge",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-089",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Damaged or missing dock bumpers allow the truck to park too close to the leveler",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-090",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "Height difference between the dock and transport vehicle bed may be greater than recommended",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-091",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "The lip actuator assembly may be damaged, causing the lip to begin extending too early in the cycle",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-092",
        "symptom_group": "G7",
        "symptom_group_name": "Lip fouls the trailer",
        "plain_language_symptom": "Lip bangs into the back of the trailer",
        "source_symptom_reference": "The lip strikes the rear of the truck as the deck raises, stops, or slows down, and lip does not extend in the locked position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Air-powered",
        "cause_or_note_summary": "The lip actuator requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Blue Giant",
        "source_document": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "document_date": "2026-08-06",
        "source_location": "Troubleshooting, printed p. 46; match the symptom heading and numbered entry where present",
        "printed_page": "46",
        "pdf_page": "46",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-093",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Total silence when you press the button",
        "source_symptom_reference": "Platform does not rise. Motor does not energize",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Motor overload device tripped",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 42; match the symptom heading and numbered entry where present",
        "printed_page": "42",
        "pdf_page": "44",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-094",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Total silence when you press the button",
        "source_symptom_reference": "Platform does not rise. Motor does not energize",
        "applicability_condition": "Starter applies to three-phase units; relay applies to single-phase units.",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Motor starter (three-phase) or motor relay (single-phase) not energizing",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 42; match the symptom heading and numbered entry where present",
        "printed_page": "42",
        "pdf_page": "44",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-095",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor hums but will not turn",
        "source_symptom_reference": "Platform does not rise. Motor hums, but does not run",
        "applicability_condition": "Three-phase units only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "No voltage present on one line; the motor is said to be single-phased",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-096",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor runs but the deck stays put",
        "source_symptom_reference": "Platform does not rise. Motor runs in reverse",
        "applicability_condition": "Three-phase units only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Reversed phase sequence",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-097",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor energizes but does not run",
        "source_symptom_reference": "Platform does not rise. Motor energizes, but does not run",
        "applicability_condition": "Single-phase units only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Line voltage too low",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-098",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor energizes but does not run",
        "source_symptom_reference": "Platform does not rise. Motor energizes, but does not run",
        "applicability_condition": "Single-phase units only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty motor centrifugal switch",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-099",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Motor energizes but does not run",
        "source_symptom_reference": "Platform does not rise. Motor energizes, but does not run",
        "applicability_condition": "Single-phase units only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty motor capacitor",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-100",
        "symptom_group": "G8",
        "symptom_group_name": "Will not self-store",
        "plain_language_symptom": "Leveler will not store itself after the truck leaves",
        "source_symptom_reference": "Platform does not automatically return to the cross-traffic position or operates abnormally",
        "applicability_condition": "Units equipped with Auto Return To Dock only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Auto return proximity switch not sensing target correctly",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-101",
        "symptom_group": "G8",
        "symptom_group_name": "Will not self-store",
        "plain_language_symptom": "Leveler will not store itself after the truck leaves",
        "source_symptom_reference": "Platform does not automatically return to the cross-traffic position or operates abnormally",
        "applicability_condition": "Units equipped with Auto Return To Dock only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty proximity switch",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-102",
        "symptom_group": "G8",
        "symptom_group_name": "Will not self-store",
        "plain_language_symptom": "Leveler will not store itself after the truck leaves",
        "source_symptom_reference": "Platform does not automatically return to the cross-traffic position or operates abnormally",
        "applicability_condition": "Units equipped with Auto Return To Dock only",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Loose or corroded wire connections, or a broken wire",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the original sound/message and equipment identity. Electrical testing or panel access requires personnel qualified for the work and the applicable safety procedure.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 43; match the symptom heading and numbered entry where present",
        "printed_page": "43",
        "pdf_page": "45",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-103",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pump operating in pressure relief mode but the deck stays put",
        "source_symptom_reference": "Platform does not rise. Pump operates in pressure relief mode",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Heavy object(s) on platform; for safety reasons the dock leveler is designed to lift only the platform's own weight",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-104",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pump operating in pressure relief mode but the deck stays put",
        "source_symptom_reference": "Platform does not rise. Pump operates in pressure relief mode",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Dock leveler binding",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-105",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pump operating in pressure relief mode but the deck stays put",
        "source_symptom_reference": "Platform does not rise. Pump operates in pressure relief mode",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Pressure relief set too low",
        "record_kind": "possible_cause",
        "source_note": "Motor full-load current limits in the manual constrain authorised adjustment; no setting or procedure is supplied here.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-106",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Platform rises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Low hydraulic fluid",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-107",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Platform rises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Contaminated hydraulic system",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-108",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Platform rises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Damaged or blocked hydraulic hose(s) or valve(s)",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-109",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck is slower than it used to be",
        "source_symptom_reference": "Platform rises slowly",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Pressure relief set too low",
        "record_kind": "possible_cause",
        "source_note": "Motor full-load current limits in the manual constrain authorised adjustment; no setting or procedure is supplied here.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-110",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Motor bogs down at the top of the stroke",
        "source_symptom_reference": "Pump motor loads down when platform reaches the full raised position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Pressure relief set too high",
        "record_kind": "possible_cause",
        "source_note": "Motor full-load current limits in the manual constrain authorised adjustment; no setting or procedure is supplied here.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 44; match the symptom heading and numbered entry where present",
        "printed_page": "44",
        "pdf_page": "46",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-111",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "Deck stops short of full height",
        "source_symptom_reference": "Platform does not rise to full height",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Low hydraulic fluid",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-112",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip drops before the deck reaches the trailer",
        "source_symptom_reference": "Lip does not stay extended when leveler lowers",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "S1 sequence valve requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-113",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Deck goes up but the lip stays hanging down",
        "source_symptom_reference": "Platform DOES rise to full height, but lip DOES NOT extend or extend fully",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Low hydraulic fluid",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-114",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Deck goes up but the lip stays hanging down",
        "source_symptom_reference": "Platform DOES rise to full height, but lip DOES NOT extend or extend fully",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "S2 sequence valve requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-115",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Deck goes up but the lip stays hanging down",
        "source_symptom_reference": "Lip does not extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "S2 sequence valve requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-116",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Lip flips out before the deck is up",
        "source_symptom_reference": "Lip extends almost immediately when the RAISE button is pressed; platform rises after lip is fully extended",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "S2 sequence valve requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-117",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck drops and catches hard on the way down",
        "source_symptom_reference": "Platform locks into safety as platform lowers; lip drops to vertical position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Platform lowering speed is too fast; NV1 needle valve requires adjustment",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-118",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck drops and catches hard on the way down",
        "source_symptom_reference": "Platform locks into safety as platform lowers; lip drops to vertical position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Faulty velocity fuse",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-119",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Deck drops and catches hard on the way down",
        "source_symptom_reference": "Platform locks into safety as platform lowers; lip drops to vertical position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Hydraulic",
        "cause_or_note_summary": "Incorrect or aged hydraulic fluid",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "-",
        "document_date": "2021-04",
        "source_location": "Troubleshooting, printed p. 45; match the symptom heading and numbered entry where present",
        "printed_page": "45",
        "pdf_page": "47",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-120",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Platform does not rise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Heavy object(s) on platform; for safety reasons the dock leveler is designed to lift only the platform's own weight",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-121",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Platform does not rise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Disconnected or broken release chain",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-122",
        "symptom_group": "G1",
        "symptom_group_name": "Will not rise",
        "plain_language_symptom": "Pull the chain and nothing happens",
        "source_symptom_reference": "Platform does not rise",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Dock leveler binding",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-123",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "It takes a hard pull and the deck barely comes up",
        "source_symptom_reference": "Platform rises slowly or does not rise to the full raised position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Heavy object(s) on platform",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-124",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "It takes a hard pull and the deck barely comes up",
        "source_symptom_reference": "Platform rises slowly or does not rise to the full raised position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Dock leveler binding",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Record the visible condition from a safe position and notify the responsible supervisor; this row does not authorize load removal, trailer movement, or a test cycle.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-125",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "It takes a hard pull and the deck barely comes up",
        "source_symptom_reference": "Platform rises slowly or does not rise to the full raised position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Insufficient main spring tension",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-126",
        "symptom_group": "G2",
        "symptom_group_name": "Rises slowly or not fully",
        "plain_language_symptom": "It takes a hard pull and the deck barely comes up",
        "source_symptom_reference": "Platform rises slowly or does not rise to the full raised position",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 30; match the symptom heading and numbered entry where present",
        "printed_page": "30",
        "pdf_page": "32",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-127",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Platform reaches full height, but the lip does not fully extend",
        "source_symptom_reference": "Platform rises to full height, but lip does not fully extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Lip assist chain disconnected or broken",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-128",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Platform reaches full height, but the lip does not fully extend",
        "source_symptom_reference": "Platform rises to full height, but lip does not fully extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Insufficient main spring tension",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-129",
        "symptom_group": "G3",
        "symptom_group_name": "Lip will not extend",
        "plain_language_symptom": "Platform reaches full height, but the lip does not fully extend",
        "source_symptom_reference": "Platform rises to full height, but lip does not fully extend",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Insufficient lip assist force",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-130",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Platform did not lower during normal walk-down",
        "source_symptom_reference": "Platform does not lower when operator walks out onto the platform",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Excessive main spring tension",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-131",
        "symptom_group": "G5",
        "symptom_group_name": "Will not lower or walk down",
        "plain_language_symptom": "Platform did not lower during normal walk-down",
        "source_symptom_reference": "Platform does not lower when operator walks out onto the platform",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-132",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip slams down during walk-down",
        "source_symptom_reference": "Lip folds too fast during normal walk-down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Insufficient lip assist force",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-133",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip slams down during walk-down",
        "source_symptom_reference": "Lip folds too fast during normal walk-down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Disconnected, worn or broken gas shock",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-134",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck pops back up under the forklift",
        "source_symptom_reference": "Platform does not stay down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Binding or stuck release chain",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-135",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck pops back up under the forklift",
        "source_symptom_reference": "Platform does not stay down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Dirt impacted in the ratchet bar teeth",
        "record_kind": "possible_cause",
        "source_note": "Poweramp HM prohibits lubricating the ratchet assembly; see printed pp. 25 and 31.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-136",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck pops back up under the forklift",
        "source_symptom_reference": "Platform does not stay down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Broken or damaged ratchet assembly teeth",
        "record_kind": "possible_cause",
        "source_note": "Poweramp HM prohibits lubricating the ratchet assembly; see printed pp. 25 and 31.",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-137",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck pops back up under the forklift",
        "source_symptom_reference": "Platform does not stay down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Disconnected or broken hold-down pivot pins",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-138",
        "symptom_group": "G6",
        "symptom_group_name": "Will not stay down",
        "plain_language_symptom": "Deck pops back up under the forklift",
        "source_symptom_reference": "Platform does not stay down",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-139",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip stays out after the truck pulls away",
        "source_symptom_reference": "Lip does not fold after truck departs",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Lip hinge binding due to lack of lubrication",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      },
      {
        "row_id": "DLT-140",
        "symptom_group": "G4",
        "symptom_group_name": "Lip will not fold back",
        "plain_language_symptom": "Lip stays out after the truck pulls away",
        "source_symptom_reference": "Lip does not fold after truck departs",
        "applicability_condition": "No additional condition stated in this row",
        "leveler_type": "Mechanical",
        "cause_or_note_summary": "Excessive lip assist force",
        "record_kind": "possible_cause",
        "source_note": "",
        "uptime_handoff_guidance": "Report the symptom and applicable manual to trained, authorized service personnel. Do not reach into the mechanism, adjust it, or enter the pit to confirm this possibility.",
        "guidance_type": "Editorial guidance; not an OSHA classification, diagnosis, or authorization",
        "evidence_type": "Source-reported; checked in named manufacturer document",
        "manufacturer": "Poweramp (Systems, LLC)",
        "source_document": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "-",
        "document_date": "2018-12",
        "source_location": "Troubleshooting, printed p. 31; match the symptom heading and numbered entry where present",
        "printed_page": "31",
        "pdf_page": "33",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "scope_limit": "Applies only to equipment/configurations covered by the named document. Not a national frequency estimate or an exhaustive diagnosis."
      }
    ],
    "edition_changes": [
      {
        "row_id": "EC-01",
        "leveler_type": "Mechanical",
        "symptom_2026": "Deck will not raise",
        "net_change": "1",
        "what_changed": "Dropped the locking roller from the hold-down cause and dropped lifting arm cam roller knocked off cam. Added lifting chain may be routed incorrectly and main spring adjustment not adjusted properly",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "5",
        "entries_2026": "6",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-02",
        "leveler_type": "Mechanical",
        "symptom_2026": "The deck does not raise quickly enough to swing the lip up into the fully extended position",
        "net_change": "0",
        "what_changed": "Both headings have seven numbered entries. The 2026 list discusses loose brush seals, a person standing on the deck, the snubber chain, and different lubrication points; several older cam/hinge details are absent. Entry counts do not measure failure frequency.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "7",
        "entries_2026": "7",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-03",
        "leveler_type": "Mechanical",
        "symptom_2026": "The lip does not lock after fully extending",
        "net_change": "2",
        "what_changed": "Added foreign object between the spools of the lip and the deck, and lip spool seizing, rusted or damaged",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "3",
        "entries_2026": "5",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-04",
        "leveler_type": "Mechanical",
        "symptom_2026": "The deck will not walk down or is difficult to walk down",
        "net_change": "3",
        "what_changed": "The 2026 heading adds difficulty walking down. It adds the engaged dock strut and expanded drag/spring-adjustment notes. Its seven entries include the same damaged-ratchet possibility twice.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "4",
        "entries_2026": "7",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-05",
        "leveler_type": "Mechanical",
        "symptom_2026": "The deck does not stay down: it springs back up after being walked down",
        "net_change": "4",
        "what_changed": "Two numbered entries in the older heading versus six in the newer heading; the newer list distinguishes release-chain, pawl, mounting, obstruction, collar, and ratchet-spring issues. No risk or frequency ranking is inferred.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "2",
        "entries_2026": "6",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-06",
        "leveler_type": "Mechanical",
        "symptom_2026": "The lip strikes the rear of the truck as the deck raises, stops, or slows down",
        "net_change": "2",
        "what_changed": "Added lip actuator assembly damaged causing the lip to extend too early, and lip actuator requires adjustment",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "2",
        "entries_2026": "4",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-07",
        "leveler_type": "Mechanical",
        "symptom_2026": "The lip will not clear the rear of the truck when attendant attempts to park the dock",
        "net_change": "-1",
        "what_changed": "Removed lip actuator assembly damaged causing the lip to be held out too late in the cycle",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "5",
        "entries_2026": "4",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-08",
        "leveler_type": "Mechanical",
        "symptom_2026": "The lip does not release or swing down when the truck departs",
        "net_change": "0",
        "what_changed": "The older similarly named heading discusses actuator damage/adjustment and lubrication. The newer heading discusses lip-lock seizure, an obstruction holding the lock, and no traffic crossing to release the lock. Some newer wording also resembles the separate older \"lip does not lock\" heading (EC-09); this is not a one-to-one replacement claim.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "3",
        "entries_2026": "3",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-09",
        "leveler_type": "Mechanical",
        "symptom_2026": "The lip does not lock (listed separately in 2018)",
        "net_change": "-3",
        "what_changed": "Three additional entries appear under this separate older heading. They must be included in the older total of 34. There is no separately identical heading in the newer table; related lip-lock wording appears elsewhere.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 21.0, printed pp. 32–33",
        "newer_location": "Section 13.0, printed pp. 26–27",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Mechanical Dock Leveler Owner's Manual 038-1083E",
        "newer_edition": "Rev.1.6, 2026-08-06",
        "entries_2018": "3",
        "entries_2026": "0",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-10",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Deck will not raise",
        "net_change": "6",
        "what_changed": "The single 2018 entry is split into four separate symptoms in the current edition, sorted by what the motor does: motor runs, motor hesitates after a hose change, total silence, and the breaker trips",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "6",
        "entries_2026": "12",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-11",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Deck will not lower",
        "net_change": "1",
        "what_changed": "Split into two entries by lip position. The 2018 travel-time setting instruction is replaced by a plain statement that the fall-safe velocity fuse is locked closed",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "1",
        "entries_2026": "2",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-12",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Deck raises slowly",
        "net_change": "1",
        "what_changed": "Split into deck raises partially and stops with the motor still running, and deck raises more slowly than normal with reservoir level normal",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "3",
        "entries_2026": "4",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-13",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Lip does not extend fully",
        "net_change": "-1",
        "what_changed": "Gained the condition oil level in reservoir is not low. Dropped the sequence valve cause",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "4",
        "entries_2026": "3",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-14",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Lip lowers slowly, worse in extreme cold (new entry)",
        "net_change": "2",
        "what_changed": "This heading is absent from the compared 2018 hydraulic table. The 2026 owner manual includes a valve-adjustment warning and a gravity/hinge note, conditional on deck lowering speed already being correct. These are notes, not two independent failed components.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "0",
        "entries_2026": "2",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      },
      {
        "row_id": "EC-15",
        "leveler_type": "Hydraulic",
        "symptom_2026": "Deck lowering speed is too slow or too fast",
        "net_change": "1",
        "what_changed": "The 2026 owner manual separately lists lowering-speed adjustment. This extra heading completes the 24-entry newer hydraulic table; the older table does not give it a separate heading.",
        "older_document": "Pit Style Dock Levelers Installation & Technical Manual 038-1073EI",
        "older_edition": "Rev.1, 2018-08-31",
        "verified_date": "2026-09-17",
        "comparison_scope": "2018 installation/technical manual versus 2026 owner manual; different documents, not proof that either applies to a particular installed unit.",
        "older_source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "newer_source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "older_location": "Section 20.0, printed pp. 31–32",
        "newer_location": "Section 12.0, printed pp. 28–29",
        "evidence_type": "Calculated entry counts and editorial comparison of source text",
        "newer_document": "Hydraulic Dock Leveler Owner's Manual 038-1084E",
        "newer_edition": "Rev.1.7, 2026-08-06",
        "entries_2018": "0",
        "entries_2026": "1",
        "count_definition": "Numbered entries, including repeated entries and notes; zero means no separately matched heading in this comparison, not absence of that fault in equipment."
      }
    ],
    "terminology_crosswalk": [
      {
        "row_id": "T-01",
        "what_people_call_it": "the deck, the ramp, the plate",
        "poweramp_term": "Platform",
        "what_it_does": "The drive-on surface a forklift crosses",
        "why_the_name_matters": "These are useful primary search terms within the respective manuals; they are not mutually exclusive vocabulary.",
        "sources": "038-1083E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Deck",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-02",
        "what_people_call_it": "the flap, the tongue, the flipper",
        "poweramp_term": "Lip",
        "what_it_does": "The hinged plate that bridges onto the trailer bed",
        "why_the_name_matters": "Both makers agree, so lip is the safe word to use on the phone",
        "sources": "038-1083E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Lip",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-03",
        "what_people_call_it": "the safety bar, the prop, the brace",
        "poweramp_term": "Maintenance Prop",
        "what_it_does": "A support component for a raised deck, used with the other supports and energy-control measures specified for that equipment.",
        "why_the_name_matters": "A component name alone does not establish the required support arrangement; the air manual contains differing inspection wording.",
        "sources": "038-1083E; 038-1084E; 038-1206E; 832-317 decal; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Dock Strut (mechanical/hydraulic); Maintenance Strut (air-powered and shown decals)",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-04",
        "what_people_call_it": "the second brace",
        "poweramp_term": "Additional means of support (not automatically a second maintenance prop)",
        "what_it_does": "A secondary support used with the strut",
        "why_the_name_matters": "Blue Giant mechanical/hydraulic manuals specify strut plus stand. Air manual sections 6.1 and 6.3 have differing inspection language; do not choose the weaker instruction. Poweramp recommendations are model-specific.",
        "sources": "038-1083E; 038-1084E; 038-1206E",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Service Stand",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-05",
        "what_people_call_it": "the catch, the pawl, the ratchet",
        "poweramp_term": "Hold-Down Mechanism (ratchet bar, ratchet pawl, pawl spring)",
        "what_it_does": "Keeps a spring-lifted deck from popping back up",
        "why_the_name_matters": "Record failure to stay down as a symptom rather than guessing which hold-down component failed.",
        "sources": "038-1083E; 4111-0007",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Ratchet Hold-Down Assembly (ratchet bar, pawl assembly, pawl retainer spring)",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-06",
        "what_people_call_it": "the pull chain, the release",
        "poweramp_term": "Platform Release Ring and hold-down release chain",
        "what_it_does": "What the operator pulls to raise a mechanical leveler",
        "why_the_name_matters": "Broken or disconnected release components are listed possibilities. Use only already-safe observations; do not expose the mechanism to inspect them.",
        "sources": "038-1083E; 4111-0007",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Hold-Down Release Ring and ratchet chain assembly",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-07",
        "what_people_call_it": "the catch legs, the drop stops",
        "poweramp_term": "Safety Legs",
        "what_it_does": "Limit how far the deck falls if trailer support is suddenly removed",
        "why_the_name_matters": "The Blue Giant mechanical manual describes a model-specific stopping function approximately 2.5 inches below dock level. This does not diagnose an unexpected drop.",
        "sources": "038-1083E",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Fall-Safe legs (mechanical fall-safe option)",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-08",
        "what_people_call_it": "the pump, the motor, the power unit",
        "poweramp_term": "Powerpack (Motor/Pump/Reservoir)",
        "what_it_does": "Raises a hydraulic deck",
        "why_the_name_matters": "A pump is one component; powerpack names the motor/pump/reservoir assembly. Confirm the actual part before ordering.",
        "sources": "038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Hydraulic Powerpack (powerpack, pump, motor, tank)",
        "source_urls": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-09",
        "what_people_call_it": "the thing that locks it up",
        "poweramp_term": "Velocity Fuse",
        "what_it_does": "Restricts rapid descent in the hydraulic system described by the applicable manual.",
        "why_the_name_matters": "A fuse may be closed or faulty. A stopped platform does not establish that the fuse is functioning correctly.",
        "sources": "038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Fall-safe velocity fuse (part # 033-661)",
        "source_urls": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-10",
        "what_people_call_it": "the little catches at the front",
        "poweramp_term": "Lip Keepers",
        "what_it_does": "Where the folded lip rests when the leveler is parked",
        "why_the_name_matters": "Agreed term across both makers",
        "sources": "038-1083E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Lip Keepers",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-11",
        "what_people_call_it": "the night lock",
        "poweramp_term": "Cross-traffic position",
        "what_it_does": "Night lock refers to the storage support/keeper context; cross-traffic position names the stored platform position.",
        "why_the_name_matters": "These terms are related, not interchangeable part names.",
        "sources": "038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Night lock",
        "source_urls": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-12",
        "what_people_call_it": "the guard plates at the sides",
        "poweramp_term": "Toe Guards",
        "what_it_does": "Close the side gap as the deck moves",
        "why_the_name_matters": "Guard type and coverage depend on the unit and its options; do not infer protection from the generic part name.",
        "sources": "038-1083E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Toe Guards",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-13",
        "what_people_call_it": "the rubber blocks on the dock face",
        "poweramp_term": "Dock Bumpers",
        "what_it_does": "Stop the trailer before it reaches the building or the lip",
        "why_the_name_matters": "Damaged or missing bumpers are listed under no-rise, lip-contact and parking symptoms. Check the applicable model rather than assuming one bumper type fits every dock.",
        "sources": "038-1083E; 038-1206E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Laminated Bumpers",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-14",
        "what_people_call_it": "the spring that flips the lip out",
        "poweramp_term": "Lip Assist Spring, Lip (Snubber) Spring, Lip Banger",
        "what_it_does": "These are different lip-extension components, not synonyms for one spring.",
        "why_the_name_matters": "In the Poweramp HM component diagram the lip banger, lip assist spring and snubber spring are separately identified.",
        "sources": "038-1083E; 4111-0007",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Lip Activating Spring and Lip Assist Spring",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-15",
        "what_people_call_it": "the big springs underneath",
        "poweramp_term": "Lift (Main) Spring Assembly",
        "what_it_does": "Raise a mechanical deck",
        "why_the_name_matters": "Stored spring energy is a servicing hazard; a generic adjustment instruction is not an equipment-specific procedure.",
        "sources": "038-1083E decal 038-1037EFS; 4111-0007 decal 1751-0728",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Main Spring / lift springs",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-16",
        "what_people_call_it": "the air bladder",
        "poweramp_term": "Not compared: Poweramp air manual is outside this matrix",
        "what_it_does": "A blower inflates it to lift the deck",
        "why_the_name_matters": "The bag, blower coupling and intake are distinct things to report to authorized service personnel.",
        "sources": "038-1206E",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Air bag",
        "source_urls": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-17",
        "what_people_call_it": "the sensor that stores it by itself",
        "poweramp_term": "Auto Return To Dock (ARTD) proximity switch and target",
        "what_it_does": "Blue Giant home sensing supports equipment interlocks; Poweramp ARTD sensing supports the optional automatic-return function.",
        "why_the_name_matters": "Related position-sensing devices can have different control jobs. A home sensor does not by itself establish automatic-return capability.",
        "sources": "038-1083E; 038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Home Interlock Sensor (part # 026-G019)",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-18",
        "what_people_call_it": "the valves on the pump",
        "poweramp_term": "RV1 main relief, S1 and S2 sequence valves, NV1 needle valve",
        "what_it_does": "Set system pressure, lip timing and lowering speed",
        "why_the_name_matters": "Valve names identify the relevant manual section; they do not establish which component caused a particular fault.",
        "sources": "038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Relief Valve, Sequence Valve, Flow Control Valve, Check Valve, Lip Solenoid",
        "source_urls": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-19",
        "what_people_call_it": "stump-out",
        "poweramp_term": "Not used as a symptom heading in the selected Poweramp tables",
        "what_it_does": "Terminology warning: manufacturers also use stump-out in product descriptions; it is not restricted to dealer slang.",
        "why_the_name_matters": "Kelley uses stump-out on its aFX product page. Describe the actual movement rather than using the term as a diagnosis.",
        "sources": "KELLEY-TERM",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Not used as a symptom heading in the selected Blue Giant tables",
        "source_urls": "https://www.kelleydocksolutions.com/products/dock-levelers/air-powered-dock-levelers/afx-air-powered-dock-leveler",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-20",
        "what_people_call_it": "the tag, the plate with the numbers",
        "poweramp_term": "Model and serial number decal on the left platform joist near the lip",
        "what_it_does": "Equipment identity and rating information; the exact fields depend on the manufacturer and unit.",
        "why_the_name_matters": "Use records or a safely accessible plate. Do not enter the pit or raise failed equipment to photograph it.",
        "sources": "038-1083E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Serial Plate Decal (038-1082EF)",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-21",
        "what_people_call_it": "end loading, below-dock loading",
        "poweramp_term": "Below Dock Endloading",
        "what_it_does": "Working the leveler below dock height to reach freight at the trailer door",
        "why_the_name_matters": "Normal loading and endloading have different model-specific sequences. Report the mode in use when the fault occurred; do not try another sequence as a workaround.",
        "sources": "038-1083E; 038-1084E; 4111-0004",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Below Level / End Loading",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      },
      {
        "row_id": "T-22",
        "what_people_call_it": "the cover plate",
        "poweramp_term": "No one-to-one equivalent established",
        "what_it_does": "A cover plate identified in the Blue Giant mechanical component list.",
        "why_the_name_matters": "The Blue Giant maintenance checklist refers to lubrication beneath part 2002286. This is not permission to lubricate a Poweramp ratchet assembly.",
        "sources": "038-1083E",
        "verified_date": "2026-09-17",
        "blue_giant_term_in_cited_edition": "Cover Plate (part # 2002286) with a lubrication point beneath it",
        "source_urls": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "evidence_type": "Source-reported terminology; explanations and cross-brand limitations are editorial",
        "source_scope": "Named document editions in the manual index; nomenclature is not a parts-compatibility claim."
      }
    ],
    "authority_gate": [
      {
        "row_id": "SG-01",
        "task_at_the_leveler": "Looking at the leveler from the dock floor while it is parked",
        "regulatory_scope": "Observation from a safe location, without exposure to unexpected movement or hazardous energy, does not itself establish covered servicing.",
        "uptime_guidance": "Record what is already visible. Do not enter the pit, raise the deck or remove a guard to obtain information.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-02",
        "task_at_the_leveler": "Taking a pallet or a load off the top of the deck",
        "regulatory_scope": "1910.147 applicability depends on the servicing task, hazardous-energy exposure and applicable exclusions/exceptions; a fault description alone does not decide it.",
        "uptime_guidance": "A load or trailer-position problem is not blanket permission to move it. Keep people off failed equipment; the responsible supervisor must plan any unloading or trailer movement safely.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-03",
        "task_at_the_leveler": "Repositioning or refusing a trailer because the lip is fouling it",
        "regulatory_scope": "1910.147 applicability depends on the servicing task, hazardous-energy exposure and applicable exclusions/exceptions; a fault description alone does not decide it.",
        "uptime_guidance": "A load or trailer-position problem is not blanket permission to move it. Keep people off failed equipment; the responsible supervisor must plan any unloading or trailer movement safely.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-04",
        "task_at_the_leveler": "Sweeping debris out of the lip hinge or the pit",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-05",
        "task_at_the_leveler": "Clearing something jammed between the deck and the pit wall",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-06",
        "task_at_the_leveler": "Greasing the lip hinge, the platform hinge or the arm points",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-07",
        "task_at_the_leveler": "Inspecting under the raised deck",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Blue Giant mechanical/hydraulic: strut plus stand. Air 6.1 distinguishes limited inspection/cleaning, but 6.3 and troubleshooting require both; obtain clarification, not a weaker support shortcut.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-08",
        "task_at_the_leveler": "Any under-deck work beyond cleaning or looking",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-09",
        "task_at_the_leveler": "Working under an air-powered leveler rated 10,000 lb or more, or with a deck longer than 108 in.",
        "regulatory_scope": "This is a model/edition-specific manufacturer support instruction, not an OSHA capacity threshold.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Blue Giant air 038-1206E Rev.1.4, section 6.3 p.15: rated capacity at least 10,000 lb OR deck longer than 108 in calls for a second strut or second stand. Resolve conflicting support descriptions with the manufacturer for the unit.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "038-1206E; OSHA-147",
        "source_urls": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-10",
        "task_at_the_leveler": "Adjusting main lift spring tension",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-11",
        "task_at_the_leveler": "Removing or replacing main lift springs",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-12",
        "task_at_the_leveler": "Adjusting a relief, sequence, flow-control or needle valve",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-13",
        "task_at_the_leveler": "Opening the control panel, or resetting an overload relay",
        "regulatory_scope": "Electrical exposures are addressed by 1910 Subpart S, including 1910.333; other machine-energy hazards can also require 1910.147 controls.",
        "uptime_guidance": "Use personnel trained/qualified for the electrical work and the applicable deenergizing, verification and lockout procedure; do not open panels or repeat resets as a generic troubleshooting step.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-333; OSHA-147; 4111-0004",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.333 | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-14",
        "task_at_the_leveler": "Electrical installation, disconnect or final connection work",
        "regulatory_scope": "Electrical exposures are addressed by 1910 Subpart S, including 1910.333; other machine-energy hazards can also require 1910.147 controls.",
        "uptime_guidance": "Use personnel trained/qualified for the electrical work and the applicable deenergizing, verification and lockout procedure; do not open panels or repeat resets as a generic troubleshooting step.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-333; OSHA-147; 4111-0004",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.333 | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-15",
        "task_at_the_leveler": "Entering the pit for any reason",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-16",
        "task_at_the_leveler": "Cleaning the ratchet bar and pawl on a mechanical hold-down",
        "regulatory_scope": "Cleaning, unjamming, inspection, adjustment or maintenance can be covered where unexpected energization/start-up or stored-energy release could cause injury; employer procedures and applicability must be assessed for the actual task.",
        "uptime_guidance": "Trained, authorized service personnel must use the employer energy-control procedure and equipment-specific support instructions. No procedure is provided here.",
        "model_specific_support_note": "Poweramp HM 4111-0007 printed pp.25,31 prohibits grease/oil on the ratchet bar/cam and lubrication of the ratchet assembly; other specified pivot lubrication is distinct.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-17",
        "task_at_the_leveler": "Pressing the stop button, or switching the control station off, and calling that isolation",
        "regulatory_scope": "1910.147(b) excludes pushbuttons, selector switches and control-circuit devices from the definition of an energy-isolating device.",
        "uptime_guidance": "A control stop is not proof of safe isolation. Authorized personnel must address all relevant energy sources and verify the required state.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; OSHA-333",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.333",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-18",
        "task_at_the_leveler": "Putting a load on the deck to hold a popping leveler down",
        "regulatory_scope": "Manufacturer stop-use instructions, not a legal classification of a fault.",
        "uptime_guidance": "Do not use a load or the overhead door to hold down a malfunctioning leveler. Keep it out of service.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-147; 038-1083E; 038-1084E; 038-1206E; 4111-0004; 4111-0007",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147 | https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us | https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us | https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf | https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      },
      {
        "row_id": "SG-19",
        "task_at_the_leveler": "Bridging a failed leveler with a plate or dock board to keep loading",
        "regulatory_scope": "1910.21(b) includes dock levelers in dockboards; 1910.26 addresses load, movement and run-off protection, including the paragraph (b)(2) exception.",
        "uptime_guidance": "Do not improvise a crossing over failed equipment. Any alternative requires its own suitable equipment, supports and safety assessment; keep the unsafe bay out of use.",
        "model_specific_support_note": "Use the applicable model/manual; support arrangement and crew size are not universal.",
        "personnel_note": "Assigned competence, authorization and crew size must fit the actual task; no universal two-person OSHA rule is claimed.",
        "sources": "OSHA-21; OSHA-22; OSHA-26",
        "source_urls": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.21 | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.22 | https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.26",
        "verified_date": "2026-09-17",
        "evidence_type": "Rule/OEM facts plus explicitly editorial task guidance; not an OSHA ruling on an individual job"
      }
    ],
    "manual_index": [
      {
        "row_id": "M-01",
        "manufacturer": "Blue Giant",
        "document_title": "Mechanical Dock Leveler Owner's Manual",
        "document_number": "038-1083E",
        "revision": "1.6",
        "issue_date": "2026-08-06",
        "access": "Public",
        "troubleshooting_section": "Sec 13.0",
        "printed_pages": "26-27",
        "symptoms_listed": "8",
        "source_url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "note": "Published edition verified at the manufacturer URL; match the equipment model, serial applicability and installed options. Not a claim that this is the newest or applicable edition for every unit.",
        "entries_in_matrix": "42",
        "verification_scope": "Cover, relevant troubleshooting section and cited supporting passages checked; site-wide latest-edition inventory not established."
      },
      {
        "row_id": "M-02",
        "manufacturer": "Blue Giant",
        "document_title": "Hydraulic Dock Leveler Owner's Manual",
        "document_number": "038-1084E",
        "revision": "1.7",
        "issue_date": "2026-08-06",
        "access": "Public",
        "troubleshooting_section": "Sec 12.0",
        "printed_pages": "28-29",
        "symptoms_listed": "11",
        "source_url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "note": "Published edition verified at the manufacturer URL; match the equipment model, serial applicability and installed options. Not a claim that this is the newest or applicable edition for every unit.",
        "entries_in_matrix": "24",
        "verification_scope": "Cover, relevant troubleshooting section and cited supporting passages checked; site-wide latest-edition inventory not established."
      },
      {
        "row_id": "M-03",
        "manufacturer": "Blue Giant",
        "document_title": "Air-Powered Dock Leveler Owner's Manual",
        "document_number": "038-1206E",
        "revision": "1.4",
        "issue_date": "2026-08-06",
        "access": "Public",
        "troubleshooting_section": "Sec 13.0",
        "printed_pages": "45-46",
        "symptoms_listed": "6",
        "source_url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "note": "Published edition verified at the manufacturer URL; match the equipment model, serial applicability and installed options. Not a claim that this is the newest or applicable edition for every unit. Differing support wording within this document is described in the article.",
        "entries_in_matrix": "26",
        "verification_scope": "Cover, relevant troubleshooting section and cited supporting passages checked; site-wide latest-edition inventory not established."
      },
      {
        "row_id": "M-08",
        "manufacturer": "Poweramp (Systems, LLC)",
        "document_title": "EH Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0004",
        "revision": "n/a",
        "issue_date": "2021-04",
        "access": "Public",
        "troubleshooting_section": "Troubleshooting",
        "printed_pages": "42-45",
        "symptoms_listed": "14",
        "source_url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "note": "Published edition verified at the manufacturer URL; match the equipment model, serial applicability and installed options. Not a claim that this is the newest or applicable edition for every unit.",
        "entries_in_matrix": "27",
        "verification_scope": "Cover, relevant troubleshooting section and cited supporting passages checked; site-wide latest-edition inventory not established."
      },
      {
        "row_id": "M-09",
        "manufacturer": "Poweramp (Systems, LLC)",
        "document_title": "HM Series Dock Leveler Owner's/User's Manual",
        "document_number": "4111-0007",
        "revision": "n/a",
        "issue_date": "2018-12",
        "access": "Public",
        "troubleshooting_section": "Troubleshooting",
        "printed_pages": "30-31",
        "symptoms_listed": "7",
        "source_url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "note": "Published edition verified at the manufacturer URL; match the equipment model, serial applicability and installed options. Not a claim that this is the newest or applicable edition for every unit.",
        "entries_in_matrix": "21",
        "verification_scope": "Cover, relevant troubleshooting section and cited supporting passages checked; site-wide latest-edition inventory not established."
      },
      {
        "row_id": "M-HIST",
        "manufacturer": "Blue Giant",
        "document_title": "Pit Style Dock Levelers Installation & Technical Manual",
        "document_number": "038-1073EI",
        "revision": "1",
        "issue_date": "2018-08-31",
        "access": "Manufacturer-authored historical PDF hosted by a third-party dealer",
        "troubleshooting_section": "20.0 hydraulic; 21.0 mechanical",
        "printed_pages": "31–33",
        "symptoms_listed": "4 hydraulic; 9 mechanical",
        "source_url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "verified_date": "2026-09-17",
        "note": "Historical comparison only. Different document from the 2026 owner manuals, not a verified direct revision chain.",
        "entries_in_matrix": "0",
        "verification_scope": "Historical table text checked; not an issuer-hosted current-operation source."
      }
    ],
    "sources": [
      {
        "source_key": "038-1083E",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Mechanical Dock Leveler Owner's Manual",
        "edition_or_date": "Rev.1.6; 2026-08-06",
        "source_class": "Manufacturer document hosted by issuer",
        "url": "https://www.bluegiant.com/getattachment/9195bfdf-7bd5-47e8-9407-03e5f650be00/038-1083E_Mechanical_Dock_Leveler_Owner_Rev.1.6_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "verification_scope": "Named edition and relevant claims checked; no field validation or universal latest-edition claim.",
        "source_location": "Troubleshooting pp.26–27; support p.9; maintenance pp.10–12; operation pp.13–15; decals p.17; components pp.18–25",
        "verification_method": "Text checked; screenshots used where available"
      },
      {
        "source_key": "038-1084E",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Hydraulic Dock Leveler Owner's Manual",
        "edition_or_date": "Rev.1.7; 2026-08-06",
        "source_class": "Manufacturer document hosted by issuer",
        "url": "https://www.bluegiant.com/getattachment/e7fb5e93-b859-48a5-ba9f-6c76e0f6fb81/038-1084E_Hydraulic_Dock_Leveler_Owner_Rev.1.7_6-Aug-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "verification_scope": "Named edition and relevant claims checked; no field validation or universal latest-edition claim.",
        "source_location": "Troubleshooting pp.28–29; support p.10; oils p.11; operation pp.13–15; interlock p.30",
        "verification_method": "Text checked; screenshots used where available"
      },
      {
        "source_key": "038-1206E",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Air-Powered Dock Leveler Owner's Manual",
        "edition_or_date": "Rev.1.4; 2026-08-06",
        "source_class": "Manufacturer document hosted by issuer",
        "url": "https://www.bluegiant.com/getattachment/0e74a99e-83ea-4d54-b30e-1a41401bee3f/038-1206E_Air-Powered_Dock_Leveler_Owner_Rev.1.4_6-AUG-2026.pdf?ext=.pdf&lang=en-us",
        "verified_date": "2026-09-17",
        "verification_scope": "Named edition and relevant claims checked; no field validation or universal latest-edition claim.",
        "source_location": "Troubleshooting pp.45–46; support sections6.1–6.3 pp.13–16; parts p.34; sample wiring p.56",
        "verification_method": "Text checked; screenshots used where available"
      },
      {
        "source_key": "4111-0004",
        "publisher": "Poweramp / Systems, LLC",
        "document": "EH Series Owner's/User's Manual",
        "edition_or_date": "April2021",
        "source_class": "Manufacturer document hosted by issuer",
        "url": "https://www.poweramp.com/files/2021-10/P_EH_4111-0004_Apr%202021.pdf",
        "verified_date": "2026-09-17",
        "verification_scope": "Named edition and relevant claims checked; no field validation or universal latest-edition claim.",
        "source_location": "Troubleshooting pp.42–45; support pp.29,42; oils pp.30–31; operation p.24; ARTD pp.38–40",
        "verification_method": "Text checked; screenshots used where available"
      },
      {
        "source_key": "4111-0007",
        "publisher": "Poweramp / Systems, LLC",
        "document": "HM Series Owner's/User's Manual",
        "edition_or_date": "December2018",
        "source_class": "Manufacturer document hosted by issuer",
        "url": "https://www.poweramp.com/files/P_HM_4111-0007_Dec2018.pdf",
        "verified_date": "2026-09-17",
        "verification_scope": "Named edition and relevant claims checked; no field validation or universal latest-edition claim.",
        "source_location": "Troubleshooting pp.30–31; ratchet warning pp.25,31; components p.9; operation p.21",
        "verification_method": "Text checked; screenshots used where available"
      },
      {
        "source_key": "038-1073EI",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Pit Style Dock Levelers Installation & Technical Manual",
        "edition_or_date": "Rev.1; 2018-08-31",
        "source_class": "Manufacturer-authored document hosted by Door Doctor",
        "url": "https://doordoctor.com/images/PDF/Mechanical_Dock_Leveler_Installation_Manual_EN.pdf",
        "verified_date": "2026-09-17",
        "verification_scope": "Historical reference text only; not authenticated as a current issuer-hosted operating manual.",
        "source_location": "Sections20.0–21.0 pp.31–33",
        "verification_method": "Readable PDF text checked; page-image fetch attempts failed"
      },
      {
        "source_key": "OSHA-147",
        "publisher": "U.S. Occupational Safety and Health Administration",
        "document": "The control of hazardous energy",
        "edition_or_date": "Federal text checked 2026-09-17",
        "source_class": "Federal regulation",
        "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.147",
        "verified_date": "2026-09-17",
        "verification_scope": "Federal general-industry context; task/exposure and jurisdiction limits retained.",
        "source_location": "1910.147(a)(1), (a)(2), (b), (c)(1), (c)(7)",
        "verification_method": "Official OSHA text retrieved through web search/browser"
      },
      {
        "source_key": "OSHA-21",
        "publisher": "U.S. Occupational Safety and Health Administration",
        "document": "Scope and definitions",
        "edition_or_date": "Federal text checked 2026-09-17",
        "source_class": "Federal regulation",
        "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.21",
        "verified_date": "2026-09-17",
        "verification_scope": "Federal general-industry context; task/exposure and jurisdiction limits retained.",
        "source_location": "1910.21(b), definition of dockboard",
        "verification_method": "Official OSHA text retrieved through web search/browser"
      },
      {
        "source_key": "OSHA-22",
        "publisher": "U.S. Occupational Safety and Health Administration",
        "document": "General requirements",
        "edition_or_date": "Federal text checked 2026-09-17",
        "source_class": "Federal regulation",
        "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.22",
        "verified_date": "2026-09-17",
        "verification_scope": "Federal general-industry context; task/exposure and jurisdiction limits retained.",
        "source_location": "1910.22(d)(1)–(3)",
        "verification_method": "Official OSHA text retrieved through web search/browser"
      },
      {
        "source_key": "OSHA-26",
        "publisher": "U.S. Occupational Safety and Health Administration",
        "document": "Dockboards",
        "edition_or_date": "Federal text checked 2026-09-17",
        "source_class": "Federal regulation",
        "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.26",
        "verified_date": "2026-09-17",
        "verification_scope": "Federal general-industry context; task/exposure and jurisdiction limits retained.",
        "source_location": "1910.26(a)–(e), including (b)(2)",
        "verification_method": "Official OSHA text retrieved through web search/browser"
      },
      {
        "source_key": "OSHA-333",
        "publisher": "U.S. Occupational Safety and Health Administration",
        "document": "Electrical work practices",
        "edition_or_date": "Federal text checked 2026-09-17",
        "source_class": "Federal regulation",
        "url": "https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.333",
        "verified_date": "2026-09-17",
        "verification_scope": "Federal general-industry context; task/exposure and jurisdiction limits retained.",
        "source_location": "1910.333(a), (b)(2)(ii)(B), (b)(2)(iv), (c)(2)",
        "verification_method": "Official OSHA text retrieved through web search/browser"
      },
      {
        "source_key": "ANSI-MH301",
        "publisher": "ANSI / MHI",
        "document": "ANSI MH30.1-2022: Performance and Testing Requirements for Dock Leveling Devices",
        "edition_or_date": "2022",
        "source_class": "Standards issuer/seller listing",
        "url": "https://webstore.ansi.org/standards/mhia/ansimh302022",
        "verified_date": "2026-09-17",
        "verification_scope": "Title, identifier and listing scope only. Full paid text not read.",
        "source_location": "Catalog listing",
        "verification_method": "Listing text only"
      },
      {
        "source_key": "BG-LIB",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Document Library",
        "edition_or_date": "Accessed 2026-09-17",
        "source_class": "Manufacturer resource directory",
        "url": "https://www.bluegiant.com/en/resources/document-library/",
        "verified_date": "2026-09-17",
        "verification_scope": "Directory located; not a complete latest-revision/access-status audit.",
        "source_location": "Directory",
        "verification_method": "Web directory text"
      },
      {
        "source_key": "KELLEY-TERM",
        "publisher": "Kelley",
        "document": "aFX Air-Powered Dock Leveler",
        "edition_or_date": "Web page checked 2026-09-17",
        "source_class": "Manufacturer product description",
        "url": "https://www.kelleydocksolutions.com/products/dock-levelers/air-powered-dock-levelers/afx-air-powered-dock-leveler",
        "verified_date": "2026-09-17",
        "verification_scope": "Confirms manufacturer use of the word stump-out; no performance/warranty claim adopted.",
        "source_location": "Opening product description",
        "verification_method": "Issuer page text"
      },
      {
        "source_key": "BG-CONTROLS",
        "publisher": "Blue Giant Equipment Corporation",
        "document": "Loading Dock Touch Controls",
        "edition_or_date": "Web page checked 2026-09-17",
        "source_class": "Manufacturer product directory",
        "url": "https://www.bluegiant.com/en/products/dock-equipment/touch-controls/",
        "verified_date": "2026-09-17",
        "verification_scope": "Identifies control families; not a model-specific reset or wiring procedure.",
        "source_location": "Touch controls list",
        "verification_method": "Issuer page text"
      }
    ],
    "onpage_crosswalk": [
      {
        "table_id": "FT-01",
        "visible_row": "1",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Foreign material lodged between the side of the deck and the pit wall",
        "matrix_row_ids": "DLT-001",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "2",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Bumpers damaged or missing, letting the truck contact and hold the lip",
        "matrix_row_ids": "DLT-002",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "3",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Equipment or goods parked on the leveler",
        "matrix_row_ids": "DLT-003",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "4",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Low hydraulic oil in power unit",
        "matrix_row_ids": "DLT-004",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "5",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Incorrect motor rotation",
        "matrix_row_ids": "DLT-005",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "6",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Relief valve is bypassing",
        "matrix_row_ids": "DLT-006",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "7",
        "observation": "Motor runs, deck stays put",
        "visible_cause_or_note_summary": "Pilot-operated check valve will not close",
        "matrix_row_ids": "DLT-007",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "8",
        "observation": "Deck hesitates, then lifts",
        "visible_cause_or_note_summary": "Air trapped in the deck lifting cylinder. *Usually occurs only after the deck cylinder hose has been replaced with a hose that was not pre-filled with oil.*",
        "matrix_row_ids": "DLT-008",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "9",
        "observation": "Total silence",
        "visible_cause_or_note_summary": "No power supply to control box",
        "matrix_row_ids": "DLT-009",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "10",
        "observation": "Total silence",
        "visible_cause_or_note_summary": "Thermal overload tripped open",
        "matrix_row_ids": "DLT-010",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "11",
        "observation": "Total silence",
        "visible_cause_or_note_summary": "Faulty control box component — fuse, touch button, contactor or transformer",
        "matrix_row_ids": "DLT-011",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "12",
        "observation": "Breaker trips",
        "visible_cause_or_note_summary": "The branch circuit is overloaded by other equipment; the circuit may not meet the power unit's requirements",
        "matrix_row_ids": "DLT-012",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "13",
        "observation": "Motor hums, won't turn",
        "visible_cause_or_note_summary": "No voltage on one line — the motor is \"single-phased\"",
        "matrix_row_ids": "DLT-095",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "14",
        "observation": "Motor runs backwards",
        "visible_cause_or_note_summary": "Phase reversed",
        "matrix_row_ids": "DLT-096",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "15",
        "observation": "Motor energizes but does not run",
        "visible_cause_or_note_summary": "Line voltage too low / faulty centrifugal switch / faulty capacitor",
        "matrix_row_ids": "DLT-097, DLT-098, DLT-099",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-01",
        "visible_row": "16",
        "observation": "Platform does not rise; the manual describes pump pressure-relief operation",
        "visible_cause_or_note_summary": "Heavy object on platform; leveler binds; pressure relief set too low",
        "matrix_row_ids": "DLT-103, DLT-104, DLT-105",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "1",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Hold-down mechanism is not releasing; release chain or handle jammed or broken",
        "matrix_row_ids": "DLT-025",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "2",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Foreign materials lodged between the side of the deck and the pit wall",
        "matrix_row_ids": "DLT-026",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "3",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Bumpers damaged or missing, letting the truck hold the lip",
        "matrix_row_ids": "DLT-027",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "4",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "The lifting chain may be routed incorrectly",
        "matrix_row_ids": "DLT-028",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "5",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Missing or broken spring(s)",
        "matrix_row_ids": "DLT-029",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "6",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Main spring adjustment not adjusted properly",
        "matrix_row_ids": "DLT-030",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "7",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Heavy object on platform — the leveler lifts only its own weight",
        "matrix_row_ids": "DLT-120",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "8",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Disconnected or broken release chain",
        "matrix_row_ids": "DLT-121",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-02",
        "visible_row": "9",
        "observation": "Chain does nothing",
        "visible_cause_or_note_summary": "Dock leveler binds — possible obstruction",
        "matrix_row_ids": "DLT-122",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "1",
        "observation": "Climbs partway, stops, motor keeps running and the unit is louder than usual",
        "visible_cause_or_note_summary": "Oil level in reservoir is low",
        "matrix_row_ids": "DLT-019",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "2",
        "observation": "Slower than it used to be, reservoir level normal",
        "visible_cause_or_note_summary": "Deck or damaged skirts dragging on the side of the pit",
        "matrix_row_ids": "DLT-020",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "3",
        "observation": "Slower than it used to be, reservoir level normal",
        "visible_cause_or_note_summary": "Pilot-operated check valve will not close",
        "matrix_row_ids": "DLT-021",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "4",
        "observation": "Slower than it used to be, reservoir level normal",
        "visible_cause_or_note_summary": "Faulty powerpack",
        "matrix_row_ids": "DLT-022",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "5",
        "observation": "Rises slowly",
        "visible_cause_or_note_summary": "Low fluid / contaminated system / damaged or blocked hose or valve / relief set too low",
        "matrix_row_ids": "DLT-106, DLT-107, DLT-108, DLT-109",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "6",
        "observation": "Motor bogs down at the top",
        "visible_cause_or_note_summary": "Pressure relief set too high",
        "matrix_row_ids": "DLT-110",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "7",
        "observation": "Stops short of full height",
        "visible_cause_or_note_summary": "Low hydraulic fluid",
        "matrix_row_ids": "DLT-111",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "8",
        "observation": "Hard pull, deck barely lifts",
        "visible_cause_or_note_summary": "Heavy object on platform",
        "matrix_row_ids": "DLT-123",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "9",
        "observation": "Hard pull, deck barely lifts",
        "visible_cause_or_note_summary": "Leveler binds",
        "matrix_row_ids": "DLT-124",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "10",
        "observation": "Hard pull, deck barely lifts",
        "visible_cause_or_note_summary": "Insufficient main spring tension",
        "matrix_row_ids": "DLT-125",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "11",
        "observation": "Hard pull, deck barely lifts",
        "visible_cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "matrix_row_ids": "DLT-126",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "12",
        "observation": "Too slow for the lip to swing out",
        "visible_cause_or_note_summary": "Deck dragging on the pit side; debris at the pit wall; side brush seals coming loose; lack of lubrication at the front and rear hinges and the four points on the arm; **someone standing on the deck**; a snubber-chain inspection prompt; lift-spring adjustment is considered only after the other listed causes",
        "matrix_row_ids": "DLT-031, DLT-032, DLT-033, DLT-034, DLT-035, DLT-036, DLT-037",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-03",
        "visible_row": "13",
        "observation": "Lifts slowly",
        "visible_cause_or_note_summary": "Damaged bag; cargo on the deck; blocked blower intake; blower uncoupled from the bag; inadequate voltage",
        "matrix_row_ids": "DLT-076, DLT-077, DLT-078, DLT-079, DLT-080",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "1",
        "observation": "Lip doesn't swing fully out *(and reservoir level is not low)*",
        "visible_cause_or_note_summary": "Lip plate bent, causing the hinge to bind",
        "matrix_row_ids": "DLT-013",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "2",
        "observation": "Lip doesn't swing fully out *(and reservoir level is not low)*",
        "visible_cause_or_note_summary": "Foreign material lodged in the lip hinge area",
        "matrix_row_ids": "DLT-014",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "3",
        "observation": "Lip doesn't swing fully out *(and reservoir level is not low)*",
        "visible_cause_or_note_summary": "Relief valve is bypassing",
        "matrix_row_ids": "DLT-015",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "4",
        "observation": "Deck reaches full height, lip doesn't extend",
        "visible_cause_or_note_summary": "Low hydraulic fluid",
        "matrix_row_ids": "DLT-113",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "5",
        "observation": "Deck reaches full height, lip doesn't extend",
        "visible_cause_or_note_summary": "S2 sequence valve requires adjustment",
        "matrix_row_ids": "DLT-114",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "6",
        "observation": "Lip flips out early, before the deck is up",
        "visible_cause_or_note_summary": "S2 sequence valve requires adjustment",
        "matrix_row_ids": "DLT-116",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "7",
        "observation": "Lip drops back before the deck reaches the trailer",
        "visible_cause_or_note_summary": "S1 sequence valve requires adjustment",
        "matrix_row_ids": "DLT-112",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "8",
        "observation": "Lip swings out then falls straight back",
        "visible_cause_or_note_summary": "Lip lock not engaging — spring broken or stretched, or the lock has seized",
        "matrix_row_ids": "DLT-038",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "9",
        "observation": "Lip swings out then falls straight back",
        "visible_cause_or_note_summary": "Lip actuator bent or broken",
        "matrix_row_ids": "DLT-039",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "10",
        "observation": "Lip swings out then falls straight back",
        "visible_cause_or_note_summary": "Foreign material in the lip lock mechanism",
        "matrix_row_ids": "DLT-040",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "11",
        "observation": "Lip swings out then falls straight back",
        "visible_cause_or_note_summary": "Foreign object between the spools of the lip and the deck",
        "matrix_row_ids": "DLT-041",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "12",
        "observation": "Lip swings out then falls straight back",
        "visible_cause_or_note_summary": "Lip spool seizing, rusted or damaged",
        "matrix_row_ids": "DLT-042",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "13",
        "observation": "Deck rises, lip stays hanging",
        "visible_cause_or_note_summary": "Lip assist chain disconnected or broken",
        "matrix_row_ids": "DLT-127",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "14",
        "observation": "Deck rises, lip stays hanging",
        "visible_cause_or_note_summary": "Insufficient main spring tension, or insufficient lip assist force",
        "matrix_row_ids": "DLT-128, DLT-129",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "15",
        "observation": "Lip stays hanging",
        "visible_cause_or_note_summary": "Debris in the lip hinge",
        "matrix_row_ids": "DLT-081",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "16",
        "observation": "Lip stays hanging",
        "visible_cause_or_note_summary": "Lip deployment mechanism damaged",
        "matrix_row_ids": "DLT-082",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "17",
        "observation": "Lip stays hanging",
        "visible_cause_or_note_summary": "Damaged air bag, or blower uncoupled from the bag",
        "matrix_row_ids": "DLT-083, DLT-084",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-04",
        "visible_row": "18",
        "observation": "Lip stays hanging",
        "visible_cause_or_note_summary": "Incorrect voltage relative to blower motor voltage",
        "matrix_row_ids": "DLT-085",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "1",
        "observation": "Lip stays out after the truck leaves",
        "visible_cause_or_note_summary": "Lip lock seized from lack of lubrication, or foreign material in the pit",
        "matrix_row_ids": "DLT-064",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "2",
        "observation": "Lip stays out after the truck leaves",
        "visible_cause_or_note_summary": "Lip lock held in the locked position by foreign material in the pit",
        "matrix_row_ids": "DLT-065",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "3",
        "observation": "Lip stays out after the truck leaves",
        "visible_cause_or_note_summary": "**No traffic has crossed the deck to break the lip lock**",
        "matrix_row_ids": "DLT-066",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "4",
        "observation": "Lip stays out after the truck leaves",
        "visible_cause_or_note_summary": "Lip hinge binding due to lack of lubrication",
        "matrix_row_ids": "DLT-139",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "5",
        "observation": "Lip stays out after the truck leaves",
        "visible_cause_or_note_summary": "Excessive lip assist force",
        "matrix_row_ids": "DLT-140",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "6",
        "observation": "Lip stuck out, won't come back in",
        "visible_cause_or_note_summary": "Lip bent or damaged; deployment mechanism damaged; debris in the lip hinge",
        "matrix_row_ids": "DLT-086, DLT-087, DLT-088",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "7",
        "observation": "Lip slams down during walk-down",
        "visible_cause_or_note_summary": "Insufficient lip assist force",
        "matrix_row_ids": "DLT-132",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "8",
        "observation": "Lip slams down during walk-down",
        "visible_cause_or_note_summary": "Disconnected, worn or broken gas shock",
        "matrix_row_ids": "DLT-133",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "9",
        "observation": "Lip lowers slowly, worse in extreme cold; **deck lowering speed is already correct**",
        "visible_cause_or_note_summary": "**A valve adjustment will not correct this problem.** Opening the needle valve will cause the deck to lower too quickly, which will in turn cause the fail-safe velocity fuse to lock",
        "matrix_row_ids": "DLT-016",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-05",
        "visible_row": "10",
        "observation": "Lip lowers slowly, worse in extreme cold; **deck lowering speed is already correct**",
        "visible_cause_or_note_summary": "The lip lowers by gravity and must pivot freely on its full-length hinge",
        "matrix_row_ids": "DLT-017",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "1",
        "observation": "Stuck up, lip does lower",
        "visible_cause_or_note_summary": "The fall-safe velocity fuse at the bottom of the deck cylinder is in the locked or closed position",
        "matrix_row_ids": "DLT-023",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "2",
        "observation": "Stuck up with the lip extended, lip does lower",
        "visible_cause_or_note_summary": "Same — velocity fuse locked closed",
        "matrix_row_ids": "DLT-024",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "3",
        "observation": "Comes down too fast or too slowly",
        "visible_cause_or_note_summary": "Lowering speed adjustment required",
        "matrix_row_ids": "DLT-018",
        "source_keys": "038-1084E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "4",
        "observation": "Drops, then catches hard partway down",
        "visible_cause_or_note_summary": "Lowering speed too fast — needle valve adjustment; faulty velocity fuse; incorrect or aged hydraulic fluid",
        "matrix_row_ids": "DLT-117, DLT-118, DLT-119",
        "source_keys": "4111-0004",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "5",
        "observation": "Won't come down",
        "visible_cause_or_note_summary": "Debris accumulated under the platform",
        "matrix_row_ids": "DLT-073",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "6",
        "observation": "Won't come down",
        "visible_cause_or_note_summary": "**Maintenance stand may still be engaged**",
        "matrix_row_ids": "DLT-074",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "7",
        "observation": "Won't come down",
        "visible_cause_or_note_summary": "Blower intake blocked",
        "matrix_row_ids": "DLT-075",
        "source_keys": "038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "8",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "Foreign material in the pit blocking the mechanism",
        "matrix_row_ids": "DLT-043",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "9",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "Side safety skirts damaged and jammed against the wall",
        "matrix_row_ids": "DLT-044",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "10",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "**The dock strut is engaged**",
        "matrix_row_ids": "DLT-045",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "11",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "The ratchet assembly may be damaged",
        "matrix_row_ids": "DLT-046, DLT-049",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "12",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "Weather seals, skirts or deck dragging against the pit wall",
        "matrix_row_ids": "DLT-047",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "13",
        "observation": "Won't walk down, or fights you",
        "visible_cause_or_note_summary": "**Lift springs improperly adjusted; tension may have been mistakenly increased to troubleshoot another problem**",
        "matrix_row_ids": "DLT-048",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "14",
        "observation": "Platform did not lower during normal walk-down",
        "visible_cause_or_note_summary": "Excessive main spring tension",
        "matrix_row_ids": "DLT-130",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-06",
        "visible_row": "15",
        "observation": "Platform did not lower during normal walk-down",
        "visible_cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "matrix_row_ids": "DLT-131",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "1",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "The pull chain is stuck in the open position",
        "matrix_row_ids": "DLT-050",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "2",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "The ratchet pawl teeth are broken",
        "matrix_row_ids": "DLT-051",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "3",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "The ratchet assembly mounts are broken",
        "matrix_row_ids": "DLT-052",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "4",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "A foreign object is preventing the ratchet pawl from locking into place",
        "matrix_row_ids": "DLT-053",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "5",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "Mis-adjusted auto collar",
        "matrix_row_ids": "DLT-054",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "6",
        "observation": "Springs back up after being walked down",
        "visible_cause_or_note_summary": "One or both springs damaged or missing in the ratchet assembly",
        "matrix_row_ids": "DLT-055",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "7",
        "observation": "Platform does not stay down",
        "visible_cause_or_note_summary": "Binding or stuck release chain",
        "matrix_row_ids": "DLT-134",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "8",
        "observation": "Platform does not stay down",
        "visible_cause_or_note_summary": "Dirt impacted in the ratchet bar teeth",
        "matrix_row_ids": "DLT-135",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "9",
        "observation": "Platform does not stay down",
        "visible_cause_or_note_summary": "Broken or damaged ratchet assembly teeth",
        "matrix_row_ids": "DLT-136",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "10",
        "observation": "Platform does not stay down",
        "visible_cause_or_note_summary": "Disconnected or broken hold-down pivot pins",
        "matrix_row_ids": "DLT-137",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-07",
        "visible_row": "11",
        "observation": "Platform does not stay down",
        "visible_cause_or_note_summary": "Damaged or worn hold-down mechanism",
        "matrix_row_ids": "DLT-138",
        "source_keys": "4111-0007",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "1",
        "observation": "Lip strikes the rear of the truck as the deck raises, stops or slows, and doesn't extend into the locked position",
        "visible_cause_or_note_summary": "Damaged or missing dock bumpers let the truck park too close",
        "matrix_row_ids": "DLT-056, DLT-089",
        "source_keys": "038-1083E; 038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "2",
        "observation": "Lip strikes the rear of the truck as the deck raises, stops or slows, and doesn't extend into the locked position",
        "visible_cause_or_note_summary": "Height difference between dock and truck bed greater than recommended",
        "matrix_row_ids": "DLT-057, DLT-090",
        "source_keys": "038-1083E; 038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "3",
        "observation": "Lip strikes the rear of the truck as the deck raises, stops or slows, and doesn't extend into the locked position",
        "visible_cause_or_note_summary": "Lip actuator assembly damaged, causing the lip to extend too early in the cycle",
        "matrix_row_ids": "DLT-058, DLT-091",
        "source_keys": "038-1083E; 038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "4",
        "observation": "Lip strikes the rear of the truck as the deck raises, stops or slows, and doesn't extend into the locked position",
        "visible_cause_or_note_summary": "Lip actuator requires adjustment",
        "matrix_row_ids": "DLT-059, DLT-092",
        "source_keys": "038-1083E; 038-1206E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "5",
        "observation": "Can't park the leveler with the truck still at the dock",
        "visible_cause_or_note_summary": "Damaged or missing dock bumpers",
        "matrix_row_ids": "DLT-060",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "6",
        "observation": "Can't park the leveler with the truck still at the dock",
        "visible_cause_or_note_summary": "Height difference greater than recommended",
        "matrix_row_ids": "DLT-061",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "7",
        "observation": "Can't park the leveler with the truck still at the dock",
        "visible_cause_or_note_summary": "Lip actuator requires adjustment",
        "matrix_row_ids": "DLT-062",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      },
      {
        "table_id": "FT-08",
        "visible_row": "8",
        "observation": "Can't park the leveler with the truck still at the dock",
        "visible_cause_or_note_summary": "The lip crown is set too high",
        "matrix_row_ids": "DLT-063",
        "source_keys": "038-1083E",
        "evidence_note": "Grouped source summaries; handoff column is Uptime editorial guidance, not an OSHA permission category."
      }
    ],
    "data_dictionary": [
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "row_id",
        "type": "text",
        "definition": "Stable entry identifier. Existing DLT/EC/T/SG identifiers are preserved; EC-15 and M-HIST are additions.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "symptom_group",
        "type": "text",
        "definition": "One of eight editorial presentation groups G1–G8; not a measured fault category.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "symptom_group_name",
        "type": "text",
        "definition": "Editorial name of the group.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "plain_language_symptom",
        "type": "text",
        "definition": "Reader-facing description, not an exact quotation or a diagnosis.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "source_symptom_reference",
        "type": "text",
        "definition": "Manufacturer symptom heading/reference, with minor punctuation/spacing normalization; consult the linked original.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "applicability_condition",
        "type": "text",
        "definition": "Conditions expressly attached to this scenario; not an instruction to test, open or energize equipment.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "leveler_type",
        "type": "text",
        "definition": "Mechanism/design scope described by the manual.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "cause_or_note_summary",
        "type": "text",
        "definition": "Brief fact/point from the named source, not a repair procedure or a probability.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "record_kind",
        "type": "text",
        "definition": "possible_cause, manufacturer_warning, design_note, inspection_prompt, or duplicate_source_entry.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "source_note",
        "type": "text",
        "definition": "Source caveat, duplicate flag, or context; blank means no additional note, not no hazard.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "uptime_handoff_guidance",
        "type": "text",
        "definition": "Editorial observation/handoff guidance; not an OEM quotation or an OSHA permission classification.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "guidance_type",
        "type": "text",
        "definition": "Explicit editorial evidence label.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "evidence_type",
        "type": "text",
        "definition": "Describes source-reported facts, calculated entry counts, or editorial synthesis.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "manufacturer",
        "type": "text",
        "definition": "Issuer/brand for the named equipment reference.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "source_document",
        "type": "text",
        "definition": "Source document. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "document_number",
        "type": "text",
        "definition": "Document number. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "revision",
        "type": "text",
        "definition": "Revision as printed; blank/not applicable is not revision zero.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "document_date",
        "type": "text",
        "definition": "Manufacturer issue date as shown; month-only values are retained rather than inventing a day.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "source_location",
        "type": "text",
        "definition": "Exact source section/page scope for spot-checking.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "printed_page",
        "type": "integer as CSV text",
        "definition": "Number printed on the cited manual page; integer, unit=page.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "pdf_page",
        "type": "integer as CSV text",
        "definition": "1-based physical PDF page for the linked file; differs from printed page in Poweramp manuals.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "source_url",
        "type": "text",
        "definition": "Working source URL retrieved during research; source availability can change.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-symptom-matrix.csv",
        "field": "scope_limit",
        "type": "text",
        "definition": "Scope limit. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "row_id",
        "type": "text",
        "definition": "Stable entry identifier. Existing DLT/EC/T/SG identifiers are preserved; EC-15 and M-HIST are additions.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "leveler_type",
        "type": "text",
        "definition": "Mechanism/design scope described by the manual.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "symptom_2026",
        "type": "text",
        "definition": "Symptom 2026. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "net_change",
        "type": "integer as CSV text",
        "definition": "entries_2026 minus entries_2018; unit=source entries. Not a machine performance comparison.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "what_changed",
        "type": "text",
        "definition": "What changed. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "older_document",
        "type": "text",
        "definition": "Older document. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "older_edition",
        "type": "text",
        "definition": "Older edition. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "comparison_scope",
        "type": "text",
        "definition": "Comparison scope. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "older_source_url",
        "type": "text",
        "definition": "Older source url. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "newer_source_url",
        "type": "text",
        "definition": "Newer source url. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "older_location",
        "type": "text",
        "definition": "Older location. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "newer_location",
        "type": "text",
        "definition": "Newer location. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "evidence_type",
        "type": "text",
        "definition": "Describes source-reported facts, calculated entry counts, or editorial synthesis.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "newer_document",
        "type": "text",
        "definition": "Newer document. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "newer_edition",
        "type": "text",
        "definition": "Newer edition. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "entries_2018",
        "type": "integer as CSV text",
        "definition": "Count of numbered entries under the matched older heading; includes duplicate/notes. Zero means no separately matched heading.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "entries_2026",
        "type": "integer as CSV text",
        "definition": "Same count rule for the newer document; not failure frequency.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-edition-changes.csv",
        "field": "count_definition",
        "type": "text",
        "definition": "How entry counts are interpreted and what they do not establish.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "row_id",
        "type": "text",
        "definition": "Stable entry identifier. Existing DLT/EC/T/SG identifiers are preserved; EC-15 and M-HIST are additions.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "what_people_call_it",
        "type": "text",
        "definition": "What people call it. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "poweramp_term",
        "type": "text",
        "definition": "Term in the cited Poweramp documents; no equivalent established is not absence from all Poweramp products.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "what_it_does",
        "type": "text",
        "definition": "What it does. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "why_the_name_matters",
        "type": "text",
        "definition": "Why the name matters. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "sources",
        "type": "text",
        "definition": "Source keys resolved through dock-leveler-sources.csv.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "blue_giant_term_in_cited_edition",
        "type": "text",
        "definition": "Term in the named Blue Giant documents; not asserted universal/current across products.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "source_urls",
        "type": "text",
        "definition": "Primary reference URLs separated by |; IDs may also point to a manufacturer-authored historical third-party copy when expressly labeled.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "evidence_type",
        "type": "text",
        "definition": "Describes source-reported facts, calculated entry counts, or editorial synthesis.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-terminology-crosswalk.csv",
        "field": "source_scope",
        "type": "text",
        "definition": "Source scope. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "row_id",
        "type": "text",
        "definition": "Stable entry identifier. Existing DLT/EC/T/SG identifiers are preserved; EC-15 and M-HIST are additions.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "task_at_the_leveler",
        "type": "text",
        "definition": "Task at the leveler. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "regulatory_scope",
        "type": "text",
        "definition": "Applicability explanation, not a legal determination for a job.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "uptime_guidance",
        "type": "text",
        "definition": "Uptime guidance. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "model_specific_support_note",
        "type": "text",
        "definition": "Conditional source support context; not directions for deploying a support.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "personnel_note",
        "type": "text",
        "definition": "Task-specific competence/authorization reminder, not a universal headcount.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "sources",
        "type": "text",
        "definition": "Source keys resolved through dock-leveler-sources.csv.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "source_urls",
        "type": "text",
        "definition": "Primary reference URLs separated by |; IDs may also point to a manufacturer-authored historical third-party copy when expressly labeled.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-authority-gate.csv",
        "field": "evidence_type",
        "type": "text",
        "definition": "Describes source-reported facts, calculated entry counts, or editorial synthesis.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "row_id",
        "type": "text",
        "definition": "Stable entry identifier. Existing DLT/EC/T/SG identifiers are preserved; EC-15 and M-HIST are additions.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "manufacturer",
        "type": "text",
        "definition": "Issuer/brand for the named equipment reference.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "document_title",
        "type": "text",
        "definition": "Document title. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "document_number",
        "type": "text",
        "definition": "Document number. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "revision",
        "type": "text",
        "definition": "Revision as printed; blank/not applicable is not revision zero.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "issue_date",
        "type": "text",
        "definition": "Manufacturer date; YYYY-MM or YYYY-MM-DD precision retained.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "access",
        "type": "text",
        "definition": "Access. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "troubleshooting_section",
        "type": "text",
        "definition": "Troubleshooting section. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "printed_pages",
        "type": "text",
        "definition": "Printed pages. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "symptoms_listed",
        "type": "text",
        "definition": "Number of manual-specific symptom headings; not distinct universal diagnoses.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "source_url",
        "type": "text",
        "definition": "Working source URL retrieved during research; source availability can change.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "note",
        "type": "text",
        "definition": "Note. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "entries_in_matrix",
        "type": "text",
        "definition": "Number of rows from that document in the 140-row matrix; zero for historical-only reference.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-manual-index.csv",
        "field": "verification_scope",
        "type": "text",
        "definition": "What was actually checked and limits on currentness or coverage.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "source_key",
        "type": "text",
        "definition": "Source key. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "publisher",
        "type": "text",
        "definition": "Publisher. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "document",
        "type": "text",
        "definition": "Document. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "edition_or_date",
        "type": "text",
        "definition": "Edition or date. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "source_class",
        "type": "text",
        "definition": "Source class. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "url",
        "type": "text",
        "definition": "Url. See the row-specific source and scope notes.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "verified_date",
        "type": "text",
        "definition": "Actual source-check date in ISO YYYY-MM-DD, separate from publication.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "verification_scope",
        "type": "text",
        "definition": "What was actually checked and limits on currentness or coverage.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "source_location",
        "type": "text",
        "definition": "Exact source section/page scope for spot-checking.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-sources.csv",
        "field": "verification_method",
        "type": "text",
        "definition": "Text and/or page-image inspection status.",
        "missing_value_rule": "Empty cell = unknown/not provided; never substitute zero. Explicit no-matched-heading zeros apply only to comparison counts.",
        "units_or_scope": "Source records/manual pages or categorical references; no sampled facilities, national denominator, frequency, costs or failure rates."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "table_id",
        "type": "text",
        "definition": "Fault table ID FT-01 through FT-08 in article order.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "visible_row",
        "type": "text",
        "definition": "1-based row within the named visible fault table.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "observation",
        "type": "text",
        "definition": "The exact displayed observation cell; not a diagnosis.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "visible_cause_or_note_summary",
        "type": "text",
        "definition": "The exact displayed cause/note cell, including portable Markdown formatting.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "matrix_row_ids",
        "type": "text",
        "definition": "Source matrix DLT IDs supporting that row, comma-separated.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "source_keys",
        "type": "text",
        "definition": "Source keys.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      },
      {
        "file": "dock-leveler-onpage-crosswalk.csv",
        "field": "evidence_note",
        "type": "text",
        "definition": "Evidence note.",
        "missing_value_rule": "Blank means not supplied; no zero imputation.",
        "units_or_scope": "Editorial table-to-source mapping only."
      }
    ]
  }
}